Calibration of In Vivo Measurement Systems Using a Voxel Phantom and the Monte Carlo Technique

JG Hunt, I Malátová, S Foltanova… - Radiation protection …, 2000 - academic.oup.com
A voxel phantom has been developed to simulate in vivo measurement systems for
calibration purposes. The calibration method presented employs a mathematical phantom …

Calibration of In-Vivo Measurement Systems and Evaluation of Lung Measurement Uncertainties Using a Mathematical Voxel Phantom

JG Hunt, L Bertelli, BM Dantas… - Radiation protection …, 1998 - academic.oup.com
A voxel phantom has been developed to simulate in vivo measurement systems for
calibration purposes. The calibration method presented here employs a mathematical …

Calibration of an In Vivo Measurement System Using a Voxel Phantom

JG Hunt, BM Dantas, E Lucena - Radiation protection dosimetry, 1998 - academic.oup.com
Although great efforts have been made to improve the physical phantoms used to calibrate
in vivo measurement systems, these phantoms represent a single average counting …

Calculation and Measurement of Calibration Factors for Bone-Surface Seeking Low Energy Gamma Emitters and Determination of 241Am Activity in a Real Case of …

JG Hunt, I Malátová, S Foltánová - Radiation protection …, 1999 - academic.oup.com
A voxel phantom has been developed to simulate in vivo measurement systems for
calibration purposes. The calibration method presented here employs a mathematical …

Voxel phantoms and Monte Carlo methods applied to in vivo measurements for simultaneous 241Am contamination in four body regions

J G. Hunt, B M. Dantas, M C. Lourenço… - Radiation protection …, 2003 - academic.oup.com
Abstract A Monte Carlo program, Visual Monte Carlo (VMC) in vivo, was written to simulate
photon transport through an anthropomorphic phantom and to detect radiation emitted from …

OEDIPE: a new graphical user interface for fast construction of numerical phantoms and MCNP calculations

D Franck, L De Carlan, N Pierrat… - Radiation protection …, 2007 - academic.oup.com
Although great efforts have been made to improve the physical phantoms used to calibrate
in vivo measurement systems, these phantoms represent a single average counting …

Computer simulations for internal dosimetry using voxel models

S Kinase, A Mohammadi, M Takahashi… - Radiation protection …, 2011 - academic.oup.com
Abstract In the Japan Atomic Energy Agency, several studies have been conducted on the
use of voxel models for internal dosimetry. Absorbed fractions (AFs) and S values have been …

Determination of the dose rate constant through Monte Carlo simulations with voxel phantoms

AD Soares, L Paixão, A Facure - Medical Physics, 2018 - Wiley Online Library
Purpose The main goal of this study was to determine the dose rate constant of
radionuclides used in Nuclear Medicine when they are biodistributed in humans. The …

Monte Carlo based voxel phantoms for in vivo internal dosimetry

JMG Ros, M Moraleda, MA López… - Radiation protection …, 2007 - academic.oup.com
The purpose of this communication is to describe briefly the computer programs developed
to generate the MCNP input file corresponding to any segmented tomographic data and its …

[PDF][PDF] Numerical efficiency calibration of in vivo measurement systems

L Hegenbart - 2009 - scholar.archive.org
Detector efficiency calibration of in vivo bioassay measurements is based on physical
anthropomorphic phantoms that can be loaded with radionuclides of the suspected …