[HTML][HTML] From bedside to bench-in vivo and in vitro evaluation of mechanically assisted cough treatment in a patient with bulbar amyotrophic lateral sclerosis

T Andersen, O Fondenes, OD Røksund… - … Medicine Case Reports, 2022 - Elsevier
When the ability to cough is impaired, secretion clearance may be assisted and augmented
by Mechanical Insufflation-Exsufflation (MI-E) treatment. In patients with Amyotrophic Lateral …

Effect of high-frequency oscillations on cough peak flows generated by mechanical in-exsufflation in medically stable subjects with amyotrophic lateral sclerosis

J Sancho, E Bures, S de La Asunción, E Servera - Respiratory care, 2016 - rc.rcjournal.com
BACKGROUND: Mechanically assisted coughing with mechanical in-exsufflation (MI-E) is
recommended for noninvasive management of respiratory secretions in amyotrophic lateral …

Usefulness of oscillations added to mechanical in-exsufflation in amyotrophic lateral sclerosis

J Sancho, E Burés, S Ferrer, E Bondía… - Respiratory Care, 2020 - rc.rcjournal.com
BACKGROUND: Assisted coughing via mechanical in-exsufflation (MI-E) is a first-line
treatment for secretion management in patients with amyotrophic lateral sclerosis (ALS) with …

A comparison of assisted cough techniques in stable patients with severe respiratory insufficiency due to amyotrophic lateral sclerosis

C Senent, JL Golmard, F Salachas… - Amyotrophic Lateral …, 2011 - Taylor & Francis
Cough can be impaired in ALS. This can result in peak cough flows (PCFs) too low for an
adequate airway clearance (< 270 l/mn). There are several cough assistance techniques …

Oscillations With Mechanical Insufflation-Exsufflation in ALS: Time to Pause and Return to Basics?

E Swingwood, NM Shah, L Rose - Respiratory care, 2021 - rc.rcjournal.com
Mechanical insufflation-exsufflation (MI-E) is a cough augmentation therapy used primarily
in patients with respiratory muscle weakness. In amyotrophic lateral sclerosis (ALS), MI-E is …

Efficacy of mechanical insufflation-exsufflation in medically stable patients with amyotrophic lateral sclerosis

J Sancho, E Servera, J Díaz, J Marín - Chest, 2004 - Elsevier
Objective To determine under what circumstances the use of mechanical insufflation-
exsufflation (MI-E) can generate clinically effective expiratory flows for airway clearance (> …

Laryngeal response patterns influence the efficacy of mechanical assisted cough in amyotrophic lateral sclerosis

T Andersen, A Sandnes, AK Brekka, M Hilland… - Thorax, 2017 - thorax.bmj.com
Background Most patients with amyotrophic lateral sclerosis (ALS) are treated with
mechanical insufflation–exsufflation (MI-E) in order to improve cough. This method often fails …

Waveforms analysis in patients with amyotrophic lateral sclerosis for enhanced efficacy of mechanically assisted coughing

J Sancho, S Ferrer, E Bures, L Fernandez-Presa… - Respiratory …, 2022 - rc.rcjournal.com
BACKGROUND: Effectiveness of mechanical assisted coughing with insufflation-exsufflation
(MI-E) in amyotrophic lateral sclerosis (ALS) depends largely on severity of bulbar …

Benefit of forced expiratory technique for weak cough in a patient with bulbar onset Amyotrophic Lateral Sclerosis

M Ishii - Journal of Physical Therapy Science, 2004 - jstage.jst.go.jp
The specific purpose of this case study was to investigate whether forced expiratory
technique (FET) improves the peak expiratory flow compared to coughing in a 53-year-old …

Long-term mechanical insufflation-exsufflation cough assistance in neuromuscular disease: patterns of use and lessons for application

M Chatwin, AK Simonds - Respiratory care, 2020 - rc.rcjournal.com
BACKGROUND: Mechanical insufflation-exsufflation (MI-E) devices increase expiratory air
flow and thereby promote increased cough peak flow (CPF) in conjunction with a cough …