Evaluation after cochlear implant surgery: Correlation of clinical outcome and imaging findings using flat-detector CT

A Stock, V Bozzato, SP Kloska, A Bozzato… - Clinical …, 2021 - Springer
Purpose Assessment of the cochlear implant (CI) electrode array position using flat-detector
computed tomography (FDCT) to test dependence of postoperative outcome on …

Evaluation of cochlear implant electrode position after a modified round window insertion by means of a 64-multislice CT

I Todt, G Rademacher, J Wagner, F Göpel… - Acta oto …, 2009 - Taylor & Francis
Conclusion. The modified round window insertion enables reproducible insertion into the
scala tympani as demonstrated by comparing the 64-CT scanning data and the surgeon's …

Scalar localization of the electrode array after cochlear implantation: clinical experience using 64-slice multidetector computed tomography

JI Lane, RJ Witte, CLW Driscoll, JK Shallop… - Otology & …, 2007 - journals.lww.com
Objective: To use the improved resolution available with 64-slice multidetector computed
tomography (MDCT) in vivo to localize the cochlear implant electrode array within the basal …

Evaluation of 4 multisection CT systems in postoperative imaging of a cochlear implant: a human cadaver and phantom study

BM Verbist, RMS Joemai… - American journal …, 2008 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Postoperative imaging of cochlear implants (CIs) needs to
provide detailed information on localization of the electrode array. We evaluated …

Verification of computed tomographic estimates of cochlear implant array position: a micro-CT and histologic analysis

J Teymouri, TE Hullar, TA Holden… - Otology & …, 2011 - journals.lww.com
Objective: To determine the efficacy of clinical computed tomographic (CT) imaging to verify
postoperative electrode array placement in cochlear implant (CI) patients. Study Design …

Intraoperative evaluation of cochlear implant electrodes using mobile cone-beam computed tomography

N Yamamoto, T Okano, H Yamazaki… - Otology & …, 2019 - journals.lww.com
Objective: To evaluate the electrode status during cochlear implantation (CI) using mobile
cone-beam CT (mCBCT). Study Design: Retrospective case review. Setting: Tertiary referral …

Imaging of electrode position after cochlear implantation with flat panel CT

D Arweiler-Harbeck, C Mönninghoff… - International …, 2012 - Wiley Online Library
Background. Postoperative imaging after cochlear implantation is usually performed by
conventional cochlear view (X‐ray) or by multislice computed tomography (MSCT). MSCT …

Post-operative evaluation of computed tomography imaging following cochlear implantation

VF Kaul, Z Brannan, J Keith, B Hittle, W Riggs… - American Journal of …, 2024 - Elsevier
Purpose This study utilized an automated segmentation algorithm to assess the cochlear
implant electrode array within the cochlea and investigate its impact on audiologic outcomes …

Cone beam CT versus multislice CT: radiologic diagnostic agreement in the postoperative assessment of cochlear implantation

V Razafindranaly, E Truy, JB Pialat… - Otology & …, 2016 - journals.lww.com
Objective: To evaluate the diagnostic concordance between multislice computed
tomography (MSCT) and cone beam computed tomography (CBCT) in the early …

Visualization of different types of cochlear implants in postoperative cone-beam CT imaging

I Burck, F Drath, MH Albrecht, H Ackermann… - Academic …, 2022 - Elsevier
Rationale and Objectives To evaluate cone-beam computed-tomography (CBCT) images of
the temporal bone for radiological delineation, metal artifacts, and accuracy for localization …