[HTML][HTML] Hemolytic anemia caused by aortic flap and inversion of felt strip after ascending aorta replacement

M Sakaguchi, T Takano - Journal of Cardiothoracic Surgery, 2016 - Springer
Backgrounds Hemolysis related to a kinked prosthetic graft or inner felt strip is a very rare
complication after aortic surgery. We describe herein a case of hemolytic anemia that …

Hemolytic anemia associated with a Teflon felt strip on a proximal anastomotic site for aortic replacement in a patient with aortic dissection

C Tokunaga, Y Enomoto, S Kanemoto… - Japanese Journal …, 2011 - pesquisa.bvsalud.org
ABSTRACT A 61-year-old man was referred to our hospital for treatment of hemolytic
anemia after ascending aortic replacement aortic dissection. Cine mode magnetic …

Postoperative early hemolytic anemia due to inverted teflon felt strip after emergency repair for type A dissection

M Hata, I Yoshitake, S Wakui… - The Thoracic and …, 2012 - thieme-connect.com
A 39-year-old man underwent emergency surgery for type A acute aortic dissection
complicated by paraplegia. However, hemolytic anemia increased significantly due to …

[HTML][HTML] Hemolytic anemia caused by kinked graft 6 months after aortic dissection repair

K Tamura, W Tatsuishi, Y Konishi, N Konno… - Journal of …, 2022 - Springer
Background Clinically insignificant hemolytic anemia is occasionally a complication of
prosthetic valve replacement. However, hemolysis related to kinked grafts is a very rare …

A case of hemolytic anemia associated with an inverted inner felt strip on a proximal anastomotic site for replacement of the ascending aorta for acute aortic dissection

H Fujita, S Takeuchi, M Okimoto… - Japanese Journal …, 2013 - pesquisa.bvsalud.org
ABSTRACT A 62-year-old man underwent replacement of the ascending aorta for a Stanford
type A acute aortic dissection. The proximal stump was reinforced with using internal and …

Aortic stenosis caused by the felt strip used in repair for acute aortic dissection

K Matsuura, H Ogino, K Minatoya… - … and Thoracic Surgery, 2004 - academic.oup.com
Objective: We report a rare complication—stenosis of the proximal anastomotic site caused
by an inside felt strip—in surgery for acute type A aortic dissection. Methods: Eight weeks …

[HTML][HTML] Patient-specific stent for hemolytic anemia due to a kinked ascending aortic graft

J Lee, HA Lim, SB Hong, YH Kim… - Journal of Thoracic …, 2023 - ncbi.nlm.nih.gov
Hemolytic anemia after thoracic aortic surgery is rare. A 69-year-old female patient, who
underwent ascending aorta replacement for acute type A aortic dissection 7 years ago, was …

Kinked graft and anastomotic stenosis-induced hemolytic anemia requiring reoperation

H Kitahara, A Yoshitake, T Hachiya, K Okamoto… - Annals of Vascular …, 2016 - Elsevier
We report a case of hemolytic anemia caused initially by narrowing of a proximal
anastomotic site and subsequently by a kinked prosthetic graft after total aortic arch …

Hemolytic anemia after operation for aortic dissection using teflon felt strips

Y Nakamura, H Ogino, H Matsuda, K Minatoya… - The Annals of thoracic …, 2008 - Elsevier
We report three cases of hemolytic anemia caused by anastomotic stenosis after surgical
treatment for aortic dissection in which internal and external Teflon (DuPont, Wilmington …

[PDF][PDF] A surgical case for hemolytic anemia after ascending and total arch replacement

Y Shingu, H Aoki, N Ebuoka, K Eya… - Annals of thoracic …, 2005 - researchgate.net
A 61-year-old man presented with consistent hemolytic anemia 15 months after ascending
and total arch replacement for DeBakey I type acute aortic dissection. The cause of …