[HTML][HTML] Reproducibility of global and segmental myocardial strain using cine DENSE at 3Â T: a multicenter cardiovascular magnetic resonance study in healthy …
… reproducibility of DENSE for measurement of whole-slice or … segmental strain assessed
using feature tracking is in the fair… ] was used with the following parameters: slice thickness = 8Â …
using feature tracking is in the fair… ] was used with the following parameters: slice thickness = 8Â …
3D motion estimation of left ventricular dynamics using MRI and track-to-track fusion
… of different two dimensional (2D) cine magnetic resonance (CMR) … two main components:
tracking myocardial points in 2D CMR … Due to high inter-slice distance1 between the short-axis …
tracking myocardial points in 2D CMR … Due to high inter-slice distance1 between the short-axis …
[HTML][HTML] Left ventricular myocardial strain quantification with two-and three-dimensional cardiovascular magnetic resonance based tissue tracking
YY Qu, J Paul, H Li, GS Ma, D Buckert… - Quantitative Imaging in …, 2021 - ncbi.nlm.nih.gov
… 3D CMR-TT modalities enable the tracking of LV myocardial … difference of 3D global peak
strains followed by establishing … and tracking comparable myocardial features of CMR cine …
strains followed by establishing … and tracking comparable myocardial features of CMR cine …
CINENet: deep learning-based 3D cardiac CINE MRI reconstruction with multi-coil complex-valued 4D spatio-temporal convolutions
… artifacts and recovery of temporal trace was found for CINENet … We measured the contrast
ratio between myocardium and … of 2D and 3D CINE in apical, mid-apical and basal slices. We …
ratio between myocardium and … of 2D and 3D CINE in apical, mid-apical and basal slices. We …
A completely automated pipeline for 3D reconstruction of human heart from 2D cine magnetic resonance slices
… into a 3D volumetric inpainting problem followed by isosurfacing from … The MR slices for the
standard cine MRI protocol are … the heart slices into four classes: LV cavity, LV myocardium, …
standard cine MRI protocol are … the heart slices into four classes: LV cavity, LV myocardium, …
MulViMotion: Shape-aware 3D myocardial motion tracking from multi-view cardiac MRI
… We extensively evaluate the proposed method on 2D cine … main contributions of this paper
are summarized as follows: … on the LV myocardium segmentation of the middle slice of the …
are summarized as follows: … on the LV myocardium segmentation of the middle slice of the …
Value CMR: Towards a Comprehensive, Rapid, Cost‐Effective Cardiovascular Magnetic Resonance Imaging
ESH Ibrahim, L Frank, D Baruah… - International Journal …, 2021 - Wiley Online Library
… cardiac functions and myocardial tissue characterization, as well … exam included the following
sequences: 3D-cine (full heart … -chamber slice reformatted from the semi-isotropic 3D-cine …
sequences: 3D-cine (full heart … -chamber slice reformatted from the semi-isotropic 3D-cine …
Fully self‐gated free‐running 3D Cartesian cardiac CINE with isotropic whole‐heart coverage in less than 2 min
… Cardiac CINE MRI is the gold standard for the assessment of … both 2D CINE and 3D CINE
at similar anatomical slice locations. … Myocardium-to-blood-pool contrast can be reduced in 3D …
at similar anatomical slice locations. … Myocardium-to-blood-pool contrast can be reduced in 3D …
High-spatial-resolution 3D whole-heart MRI T2 mapping for assessment of myocarditis
… tissue injury was not detected with conventional three-slice 2D T2 mapping, whereas 3D T2
map reveals larger extent of myocardial … ejection fraction at cardiac cine MRI (left ventricular …
map reveals larger extent of myocardial … ejection fraction at cardiac cine MRI (left ventricular …
Cine and late gadolinium enhancement MRI registration and automated myocardial infarct heterogeneity quantification
F Guo, PRP Krahn, T Escartin… - Magnetic Resonance …, 2021 - Wiley Online Library
… cine and 3D LGE in 10 pigs with myocardial infarct. The 2D … 3D LGE was performed ~10-15
min following injection of … , we used 2D cine stacks of thick short-axis slices, and the partial …
min following injection of … , we used 2D cine stacks of thick short-axis slices, and the partial …