Fiber optic radioluminescent probes for radiation therapy dosimetry
A Darafsheh - Optical Fibers and Sensors for Medical …, 2019 - spiedigitallibrary.org
… In this work, recent progress toward minimizing the impact of Čerenkov radiation and … through
using spectroscopic methods, specialty fiber optics, and undoped fibers is briefly reviewed. …
using spectroscopic methods, specialty fiber optics, and undoped fibers is briefly reviewed. …
[HTML][HTML] In vivo dosimetry in brachytherapy: Requirements and future directions for research, development, and clinical practice
GP Fonseca, JG Johansen, RL Smith… - … and imaging in radiation …, 2020 - Elsevier
… The brachytherapy community promoted developments in in vivo dosimetry (IVD) through
research groups and small companies. Although very few of the systems have been used …
research groups and small companies. Although very few of the systems have been used …
Development of fibre-optic dosimetry system as a quality assurance tool for High Dose Rate Brachytherapy
M Al Towairqi - 2020 - ro.uow.edu.au
… experts have researched and developed new cancer treatment techniques. This chapter
will briefly summarise the developments in the area of radiotherapy treatment techniques from …
will briefly summarise the developments in the area of radiotherapy treatment techniques from …
A swallowable X-ray dosimeter for the real-time monitoring of radiotherapy
… changes during gastrointestinal radiotherapy. The capsule comprises a flexible optical
fibre … We next evaluated the dose response of the optical fibre with embedded NaLuF 4 :Tb@…
fibre … We next evaluated the dose response of the optical fibre with embedded NaLuF 4 :Tb@…
[HTML][HTML] Fibre-optic dosimetry for MRI-LINACs: a mini-review
… presented a new opportunity for real-time image guidance during radiotherapy treatments, …
will be generated in plastic optical fibres during LINAC dosimetry. Cerenkov radiation is …
will be generated in plastic optical fibres during LINAC dosimetry. Cerenkov radiation is …
Recent advances and clinical applications of plastic scintillators in the field of radiation therapy
S Beddar, I Tendler, F Therriault-Proulx… - … : Chemistry and …, 2021 - Springer
… at the latest developments in plastic scintillation dosimetry over the past 5–6 years across
three radiation therapy … elements within optical fiber dosimetry setups, an example is included …
three radiation therapy … elements within optical fiber dosimetry setups, an example is included …
[HTML][HTML] Optical filter-embedded fiber-optic radiation sensor for ultra-high dose rate electron beam dosimetry
DH Jeong, M Lee, H Lim, SK Kang, K Lee, SJ Lee… - Sensors, 2021 - mdpi.com
… than those of conventional radiotherapy. In this study, a … an optical filter, and a plastic optical
fiber (POF) for dosimetry of … from a 6 MeV LINAC at Dongnam Institute of Radiological and …
fiber (POF) for dosimetry of … from a 6 MeV LINAC at Dongnam Institute of Radiological and …
[HTML][HTML] Editorial to the Special Issue Optical Fiber Sensors in Radiation Environments
… a pulsed electron Clinac beam in use for radiotherapy, for the first time. … development of
luminescence-based sensors. MCVD is the reference method for the fabrication of optical fibers …
luminescence-based sensors. MCVD is the reference method for the fabrication of optical fibers …
Measurement of scattered rays from different materials using an inorganic scintillator based optical fiber sensor and its application in radiotherapy
T Xie, B He, Q Shi, J Qian, W Hao, S Li… - Biomedical Physics …, 2022 - iopscience.iop.org
… Recently, the role of optical fiber sensors in the field of therapeutic radiation dosimetry has …
scintillating fluorescence is transmitted through an optical fiber towards a distal photodetector. …
scintillating fluorescence is transmitted through an optical fiber towards a distal photodetector. …
[PDF][PDF] Optical fibre dosimetry in external beam radiotherapy
M Alharbi - 2020 - academia.edu
… 3.1 Schematic representation of the inorganic optical fibre sensor for external beam
radiotherapy, showing a 700 μm diameter and 7 mm deep cavity in the core of a PMMA plastic …
radiotherapy, showing a 700 μm diameter and 7 mm deep cavity in the core of a PMMA plastic …