[HTML][HTML] Validation of a Monte Carlo framework for out-of-field dose calculations in proton therapy
M De Saint-Hubert, N Verbeek, C Bäumer… - Frontiers in …, 2022 - frontiersin.org
… realistic proton treatment of a brain tumor, a clinically applied … beam model implemented in
RayStation were used to fully … As the role of proton beam therapy is continuously increasing, …
RayStation were used to fully … As the role of proton beam therapy is continuously increasing, …
Clinical validation of a GPU-based Monte Carlo dose engine of a commercial treatment planning system for pencil beam scanning proton therapy
… 636 approved plans with 3361 beams computed with the clinically implemented CPU-MC …
well as different target geometries and proton beam energies simulated all differ between the …
well as different target geometries and proton beam energies simulated all differ between the …
Automated Monte-Carlo re-calculation of proton therapy plans using Geant4/Gate: implementation and comparison to plan-specific quality assurance measurements
AH Aitkenhead, P Sitch, JC Richardson… - The British Journal of …, 2020 - academic.oup.com
… This study describes the MC system implemented at The Christie for re-calculation of proton
… of the clinical service, covering the full range of clinical indications eligible within the NHS …
… of the clinical service, covering the full range of clinical indications eligible within the NHS …
[HTML][HTML] Implementation of a dose calculation algorithm based on Monte Carlo simulations for treatment planning towards MRI guided ion beam therapy
… At MedAustron, a library of 255 energies is clinically used for proton beams, fulfilling the
treatment planning requirements of placing Bragg peaks between 30 and 380 mm water-…
treatment planning requirements of placing Bragg peaks between 30 and 380 mm water-…
A Monte Carlo based radiation response modelling framework to assess variability of clinical RBE in proton therapy
J Eulitz, B Lutz, P Wohlfahrt, A Dutz… - Physics in Medicine …, 2019 - iopscience.iop.org
… RBE of 1.1 is applied in proton beam treatment planning. However, a controversial … clinical
impact and verifying clinical evidence on a variable RBE. We implemented a full Monte Carlo …
impact and verifying clinical evidence on a variable RBE. We implemented a full Monte Carlo …
Verification of a Monte Carlo dose calculation engine in proton minibeam radiotherapy in a passive scattering beamline for preclinical trials
C Guardiola, L De Marzi… - The British Journal of …, 2020 - academic.oup.com
… strategy 1 in which irradiation is performed by using arrays of narrow (≤1 mm) proton
beams. pMBRT has already been implemented in our clinical centre (Institut Curie-Proton …
beams. pMBRT has already been implemented in our clinical centre (Institut Curie-Proton …
Integrating an open source Monte Carlo code “MCsquare” for clinical use in intensity‐modulated proton therapy
… MCsquare was successfully commissioned for a synchrotron-based proton beam therapy …
resampling and implementing LET model-dependent biological dose calculation capabilities…
resampling and implementing LET model-dependent biological dose calculation capabilities…
A standardized commissioning framework of Monte Carlo dose calculation algorithms for proton pencil beam scanning treatment planning systems
… formula implementation of HU to RSP for our pencil beam dose calculation algorithm in
Eclipse. … Building a proton beam model from measured data is an inverse modeling problem for …
Eclipse. … Building a proton beam model from measured data is an inverse modeling problem for …
NRG oncology survey of Monte Carlo dose calculation use in US proton therapy centers
… dose calculation algorithm plays an important role in the accuracy and quality of proton beam
therapy… the feasibility of implementing MC in all clinical trials involving proton therapy. The …
therapy… the feasibility of implementing MC in all clinical trials involving proton therapy. The …
Monte Carlo implementation of new algorithms for the evaluation of averaged-dose and-track linear energy transfers in 62 MeV clinical proton beams
G Petringa, L Pandola, S Agosteo… - Physics in Medicine …, 2020 - iopscience.iop.org
… We exploited the power of the Geant4 Monte Carlo … ) calculation in 62 MeV clinical proton
beams. The definitions of the averaged LET dose and LET track were extended, so as to fully …
beams. The definitions of the averaged LET dose and LET track were extended, so as to fully …