[HTML][HTML] Preliminary experience with the new Amplatzer™ Trevisio™ delivery system in transcatheter atrial septal defect closures in children

RN Haddad, D Khraiche, D Bonnet, M Meot… - Frontiers in …, 2021 - frontiersin.org
… However, the original stiffer delivery wire of the ASO transferred considerable tension to
the occluder and the atrial septum increasing the risks of device embolization and procedure …

Trans-catheter atrial septal defect closure with the new GORE® Cardioform ASD occluder: First European experience

G Santoro, B Castaldi, M Cuman, A Di Candia… - International Journal of …, 2021 - Elsevier
… (Amplatzer Septal Occluder or Amplatzer-like devices) or … types of devices or to the results
of the preliminary studies with … as well as early outcome of percutaneous ASD closure with the …

Percutaneous Closure of Atrial Septal Defects with the Memopart Atrial Septal Occluder: The Early-Term Results of a Multicenter Study

A Baykan, M Bilici, N Narin, A Erdem, K Uzum… - Pediatric …, 2022 - Springer
Atrial septal defect closure was applied successfully in all … septal occluder is a safe and
effective device for ASD closure. In … occlusion device, which is extremely similar to the Amplatzer

Long-term follow-up of percutaneous secundum-type atrial septal defect closure using Amplatzer Septal Occluder since 1995: a single-centre study

P Olejnik, P Tittel, Z Venczelova, M Kardos… - Cardiology in the …, 2024 - cambridge.org
… only early after the Amplatzer Septal Occluder implantation.… results of our study showed that
percutaneous closure of secundum-type atrial septal defect using Amplatzer Septal Occluder

Transcatheter closure of perimembranous ventricular septal defects using different generations of amplatzer devices: multicenter experience

R Mijangos-Vázquez, A El-Sisi… - Journal of …, 2020 - Wiley Online Library
… of patent ductus arteriosus (PDA) and atrial septal defects (… Since this early experience,
many authors have published … results in VSD closure referring to the use of softer devices with …

Use of the GORE® CARDIOFORM Septal Occluder for percutaneous closure of secundum atrial septal defects: results of the multicenter US IDE trial

MJ Gillespie, AJ Javois, P Moore… - Catheterization and …, 2020 - Wiley Online Library
Early studies of ASD device closure used a residual defect size of >2.0 mm to denote closure
… advantage to the Amplatzer device is the smaller (6F–7F) delivery sheath required to treat …

[HTML][HTML] Transcatheter closure of atrial and ventricular septal defects: JACC focus seminar

ME Turner, I Bouhout, CJ Petit, D Kalfa - Journal of the American College of …, 2022 - Elsevier
… of early devices for transcatheter closure of septal defects in the … atrial septal defects (ASDs)
and ventricular septal defects (… of an Amplatzer Muscular VSD Occluder, the defect is closed

[HTML][HTML] Outcomes of device closure of atrial septal defects

PS Rao - Children, 2020 - mdpi.com
… invented the buttoned device decided not to seek pre-market … -up results of Amplatzer device
occlusion of secundum atrial … for occlusion of atrial septal defect by the Amplatzer Septal

[HTML][HTML] The efficacy and safety of using amplatzer for transcatheter closure of atrial septal defect in small children with less than 10 kg

M Ghaderian, MR Sabri, AR Ahmadi… - Arya …, 2019 - ncbi.nlm.nih.gov
… Implantation of atrial septal defect (ASD) device occluder in … in their early years, and the
smaller the size of the defect, the … good results in our study and had no major complications. …

A novel closure device for atrial septal defect: Much more to learn and experience

PH Lee, DW Park - International Journal of …, 2021 - internationaljournalofcardiology.com
… Despite the potential feasibility of early-generation occluder devices, open heart surgery
remained as the standard treatment until the advent of the AMPLATZERseptal occluder (ASO…