[HTML][HTML] … of Three-Dimensional Conformal Radiotherapy (3D-CRT) and Intensity-Modulated Radiation Therapy (IMRT) Techniques in Patients With Head and Neck …
S Manam, R Teja, AR Pb, SK Azharuddin - Cureus, 2024 - ncbi.nlm.nih.gov
… , the mean dose for the SCM and MCM in 3D-CRT was 57.55 … the mean dose to the DARS
in the 3D-CRT and IMRT groups. … mean dose received by the DARS in the 3D-CRT and IMRT …
in the 3D-CRT and IMRT groups. … mean dose received by the DARS in the 3D-CRT and IMRT …
Comparative study assessing QoL in HNSCC patients treated with Radical Radiation with IMRT vs 3DCRT
M Mukherjee, J Bhattacharya… - Radiotherapy and …, 2019 - postersessiononline.eu
… cancer) undergoing radical radiotherapy either alone or with … doses with conventional
fractionation using either IMRT or … in 3D-CRT group over IMRT group not only during radiation …
fractionation using either IMRT or … in 3D-CRT group over IMRT group not only during radiation …
Outcomes between i ntensity‐modulated radiation therapy versus 3D‐conformal in early stage glottic cancer
A Amini, R Morgan, E Meyer, K Fakhoury… - Head & …, 2021 - Wiley Online Library
… This is in contrast to 3D-CRT where an intermediate dose of … for IMRT compared to 3D-CRT
is that there is no dose … who received either IMRT or 3D-CRT, excluding patients who …
is that there is no dose … who received either IMRT or 3D-CRT, excluding patients who …
[HTML][HTML] Identifying organs at risk for radiation-induced late dysphagia in head and neck cancer patients
J Hedström, L Tuomi, C Finizia, C Olsson - Clinical and Translational …, 2019 - Elsevier
… radiation therapy (IMRT/VMAT) with specified dose constraints to the parotid glands. Prescribed
doses … Structure-specific dose-volume histograms (DVH) with a dose bin size of 0.5 Gy …
doses … Structure-specific dose-volume histograms (DVH) with a dose bin size of 0.5 Gy …
… of Breast Cancer Radiotherapy Techniques Regarding Secondary Cancer Risk and Normal Tissue Complication Probability–Modelling and Measurements Using a …
M Vogel, J Gade, B Timm, M Schürmann… - Frontiers in …, 2022 - frontiersin.org
… , as 3D-CRT was replaced by IMRT as standard in our clinic during the observation period.
… These doses correspond to the values we observe in the “3D-CRT + sequential boost” and “…
… These doses correspond to the values we observe in the “3D-CRT + sequential boost” and “…
[HTML][HTML] Dosimetric impact of weight loss and anatomical changes at organs at risk during intensity-modulated radiotherapy for head-and-neck cancer
KM Radaideh - Journal of Radiation Research and Applied Sciences, 2020 - Elsevier
… using intensity-modulated radiation therapy (IMRT) requires highly accurate techniques to
keep the radiation to organs at risk … dose distribution and the complexity of using IMRT leads to …
keep the radiation to organs at risk … dose distribution and the complexity of using IMRT leads to …
3-Dimensional Conformal Radiotherapy versus Intensity Modulated Radiotherapy in Postoperative Head and Neck Cancers: Comparative Analysis of Dosimetric …
A Bhadri, P Kumar, P Kumar, R Sachan… - SRMS JOURNAL OF …, 2023 - jmssrms.in
… radiotherapy techniques - 3D CRT and IMRT- in patients with postoperative head and neck
… that when compared to 3DCRT, IMRT treatment plan had increased dose coverage to PTV, …
… that when compared to 3DCRT, IMRT treatment plan had increased dose coverage to PTV, …
Volumetric and Dosimetric Inconstancy of Parotid Glands and Tumor in Head and Neck Cancer during IMRT
… radiotherapy (3D-CRT), intensitymodulated radiation therapy (… IMRT has superior results
over conventional 3D-CRT [12–14]… of dose around the target, any negligence during the IMRT …
over conventional 3D-CRT [12–14]… of dose around the target, any negligence during the IMRT …
Second cancer risk evaluation from breast radiotherapy using dose-response models
M Hassan, EM Attalla - … Journal of Biomedical Engineering and …, 2021 - journals.ekb.eg
… They concluded that the second cancer risk after 3D-CRT or t-IMRT is lower than for m-IMRT
or VMAT by about 34% for the linear model and 50% for the linearexponential, and plateau …
or VMAT by about 34% for the linear model and 50% for the linearexponential, and plateau …
Three-dimensional conformal radiotherapy-based or intensity-modulated radiotherapy-based concurrent chemoradiotherapy in patients with thoracic esophageal …
WC Lin, CL Chang, HL Hsu, KSP Yuan, ATH Wu… - Cancers, 2019 - mdpi.com
… the treatment outcomes of IMRT-CRT-based or 3D-CRT-based CCRT for TESCC. Our
findings suggest that, compared with 3D-CRT, standard radiation doses of IMRT improve overall …
findings suggest that, compared with 3D-CRT, standard radiation doses of IMRT improve overall …