Imaging of 99mTc-DMSA and 18F-FDG in humans using a Si/CdTe Compton camera

T Nakano, M Sakai, K Torikai, Y Suzuki… - Physics in Medicine …, 2020 - iopscience.iop.org
… the distributions of gamma-ray-emitting radioisotopes (RI) based on … Nevertheless, several
issues need to be addressed before … −6 for 511 keV photons for a point source placed 10 cm

[HTML][HTML] Seismic evidence for near solid-body rotation in two Kepler subgiants and implications for angular momentum transport

S Deheuvels, J Ballot, P Eggenberger, F Spada… - Astronomy & …, 2020 - aanda.org
… ν add , we found that values of ν add > 5 × 10 4 cm 2 s −1 are … All these observations point
to the existence of an efficient … be required to identify the source of this disagreement, but this …

State-of-the-art mobile radiation detection systems for different scenarios

L Marques, A Vale, P Vaz - Sensors, 2021 - mdpi.com
… for source location. This study reviews and discusses the research advancements in the field
of gamma-… camera with only 1 kg and 10 cm 2 size (Figure 12). The camera is composed by …

Ultrafast timing enables reconstruction-free positron emission imaging

SI Kwon, R Ota, E Berg, F Hashimoto, K Nakajima… - Nature …, 2021 - nature.com
… X-ray and gamma-ray photons are widely used for imaging … Once larger-scale systems
with more efficient detectors are … the known location of the source, across a distance of 10 cm, …

AAPM WGDCAB Report 372: A joint AAPM, ESTRO, ABG, and ABS report on commissioning of model‐based dose calculation algorithms in brachytherapy

L Beaulieu, F Ballester, D Granero… - Medical …, 2023 - Wiley Online Library
… negligible dose differences within 10 cm of the source … tools such as dose-difference histograms
and gamma-index analysis … author of the report are found at the close of this document. …

Resolving acceleration to very high energies along the jet of Centaurus A

Nature, 2020 - nature.com
… The source is also positionally close to an ultrahigh-energy cosmic-ray hotspot 21 . Gamma-…
, providing excellent observing conditions for sources located in the Southern Hemisphere. It …

Radiation therapy for brain metastases: an ASTRO clinical practice guideline

V Gondi, G Bauman, L Bradfield, SH Burri… - Practical radiation …, 2022 - Elsevier
found that for single-fraction SRS for brain metastases, total irradiated volumes (normal brain
plus target volumes) of 5 cm 3 , 10 cm 3 , or >15 cm 3 … brain metastases after Gamma Knife …

[HTML][HTML] Mouse navigation strategies for odor source localization

A Liu, AE Papale, J Hengenius, K Patel… - Frontiers in …, 2020 - frontiersin.org
… this occurred the mouse started within 10 cm of the odor spot)… focused on either the time
before a spot was found, or the full … ’s nose was located at a distance l = 5 cm from the body at …

[HTML][HTML] Reducing the impact of radioactivity on quantum circuits in a deep-underground facility

L Cardani, F Valenti, N Casali, G Catelani… - Nature …, 2021 - nature.com
placed in this radio-cleaned holder was measured deep underground in a cryostat surrounded
by a wall of 10 cm thick … Cosmic rays, indeed, produce gamma showers in the materials …

An overview of the method of fundamental solutions—Solvability, uniqueness, convergence, and stability

AHD Cheng, Y Hong - Engineering Analysis with Boundary Elements, 2020 - Elsevier
… show that the sources need to stay close to the boundary, … sphere, to create distributed sources
that can be placed on the … body as the summation of a uniform flow and point sources(12) …