Comparison of BNCT dosimetry calculations using different GEANT4 physics lists

Z Chen, P Yang, Q Lei, Y Wen, D He… - Radiation protection …, 2019 - academic.oup.com
… The total absorbed dose and component dose in the phantom calculated by … the neutron
physics model of the Geant4 physics list when using Geant4 to study BNCT dose calculations. …

Computation speeds and memory requirements of mesh-type ICRP reference computational phantoms in Geant4, MCNP6, and PHITS

YS Yeom, MC Han, C Choi, H Han, B Shin… - Health …, 2019 - journals.lww.com
Radiological Protection dose coefficient calculations. In the present study, the performance
of major Monte Carlo particle transport codes, ie, Geant4… in Geant4 for simulation of neutrons

GEANT4 Simulation of Photoneutron Spectrum from Medical Linear Accelerator

A Chernyaev, M Belikhin, E Lykova… - Quantum Beam …, 2023 - mdpi.com
calculation of neutrons. Geng et al. [22] and Apostolakis et al. … Calculation of radiation
protection for the accelerator can … the use of CR-39 for photoneutron dosimetry in a water phantom

[PDF][PDF] Geant4 Studies On Various Scintillation Detection Systems And Dose Values At Different Radiation Types

H TILAVER - 2022 - etheses.whiterose.ac.uk
radiation energy can have very large biological consequences, dose values in water-equivalent
phantom for use … After determining the dose values, the study on the interaction of the CsI…

Design of a protective shield for a radiological emergency intervention using Monte Carlo simulation and an anthropomorphic phantom

Y El-Ouardi, A Aknouch, A Dadouch, M Mouhib… - Radiation and …, 2022 - Springer
… with the Geant4 simulation toolkit using a digital anthropomorphic … was to design a radiation
shield to protect an operator during the … The Geant4 toolkit allows for calculation of the dose

Monte Carlo GEANT4 Simulation of the Deposited Doses by Different Types of Particles Estimated in a Water Phantom

C Elmoujaddidi, I Ghazi, H Chakir, R Sebihi… - Physics of Particles and …, 2022 - Springer
… In the second place, we calculated the deposited dose of the … and dose distributions in a
water phantom and homogeneous … In radiation protection measurements, the unit of absorbed …

Monte Carlo calculation of the organ equivalent dose and effective dose due to immersion in a 16N beta source in air using the ICRP reference phantoms

JM Gómez-Ros, M Moraleda, P Arce, DK Bui… - Radiation …, 2021 - Elsevier
… the calculation of the quantities and to assure the homogeneity … -called Shielding physics
list that considers the Geant4 standard … with different situations of the radiation protection field. …

[PDF][PDF] A passive method for absolute dose evaluation of photoneutrons in radiotherapy

KR Rajesh, RG Raman, MM Musthafa, CV Midhun… - … Journal of Radiation …, 2020 - sid.ir
… is calculated using Geant4. The composite photoneutron … The fast neutron dose equivalent
measured at the phantom surface … -neutron spectrum clearly shows the heterogeneous photo-…

Comparison of penh, fluka, and Geant4/topas for absorbed dose calculations in air cavities representing ionization chambers in high‐energy photon and proton …

KS Baumann, F Horst, K Zink, C Gomà - Medical physics, 2019 - Wiley Online Library
… photon beam14 applied in an homogeneous field of 10 × 10 cm urn:… the source and the water
phantom was filled with vacuum. … -math-0078 water phantom when irradiating with a pencil …

Report on G4‐Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group

P Arce, D Bolst, MC Bordage, JMC Brown… - Medical …, 2021 - Wiley Online Library
… algorithms, and for radiation protection assessments. In the medical physics domain, …
The plots show the attenuation coefficients as calculated using Geant4 against the NIST …