Study of out‐of‐field dose in photon radiotherapy: A commercial treatment planning system versus measurements and Monte Carlo simulations
B Sánchez‐Nieto, KN Medina‐Ascanio… - Medical …, 2020 - Wiley Online Library
… used to determine dose from external beam RT includes measurements, treatment planning
systems (TPSs), and Monte Carlo … use of film dosimetry for the commissioning and checking …
systems (TPSs), and Monte Carlo … use of film dosimetry for the commissioning and checking …
Beam modeling and beam model commissioning for Monte Carlo dose calculation‐based radiation therapy treatment planning: Report of AAPM Task Group 157
… calculation and dosimetry verification for advanced radiotherapy techniques has been … for
Monte Carlo (MC)–based treatment planning system (TPS). Note that the dose difference is the …
Monte Carlo (MC)–based treatment planning system (TPS). Note that the dose difference is the …
Validation of linear energy transfer computed in a Monte Carlo dose engine of a commercial treatment planning system
… Monte Carlo dose engines which are typically not used clinically. We present the first validation
… LET D against calculations by the Monte Carlo dose engines of the Raystation treatment …
… LET D against calculations by the Monte Carlo dose engines of the Raystation treatment …
[HTML][HTML] … a treatment planning system developed for clinical boron neutron capture therapy and validation against an independent Monte Carlo dose calculation system
N Hu, H Tanaka, R Kakino, S Yoshikawa, M Miyao… - Radiation …, 2021 - Springer
… Furthermore, to validate and verify the new planning system, the dose distribution inside an
… a BNCT treatment planning system SERA and an in-house developed Monte Carlo dose …
… a BNCT treatment planning system SERA and an in-house developed Monte Carlo dose …
Clinical validation of a GPU-based Monte Carlo dose engine of a commercial treatment planning system for pencil beam scanning proton therapy
… We presented the dosimetric validation of a clinical version of Monte Carlo … ones used in
this study no significant dosimetric differences have been introduced and the clinical validation …
this study no significant dosimetric differences have been introduced and the clinical validation …
A standardized commissioning framework of Monte Carlo dose calculation algorithms for proton pencil beam scanning treatment planning systems
… The verified phase-space parameters were used in our TOPAS beam model. Equation (1)
describes how to use TOPAS to adjust TPS MC simulation for code benchmark or validation …
describes how to use TOPAS to adjust TPS MC simulation for code benchmark or validation …
[HTML][HTML] Dose calculation comparisons between three modern treatment planning systems
C Bosse, G Narayanasamy, D Saenz… - Journal of medical …, 2020 - journals.lww.com
… -Carlo (MC)-based dose calculation engine. The aim of this study is to verify and compare the
Monaco-based dose … Issues associated with clinical implementation of Monte Carlo-based …
Monaco-based dose … Issues associated with clinical implementation of Monte Carlo-based …
[HTML][HTML] Out-of-field dose calculation by a commercial treatment planning system and comparison by monte carlo simulation for varian TrueBeam®
NS Shine, R Paramu, M Gopinath… - Journal of medical …, 2019 - journals.lww.com
… The calculation accuracy of treatment planning systems (TPSs) drops drastically when the
… In this study, the accuracy of out-of-field dose calculated by a TPS, used with a TrueBeam®(…
… In this study, the accuracy of out-of-field dose calculated by a TPS, used with a TrueBeam®(…
The commissioning and validation of Monaco treatment planning system on an Elekta Versa HD linear accelerator
… overall accuracy in the radiotherapy process. This study … beam model validation of a Monaco
treatment planning system on … Monte Carlo (MC) algorithms are the gold standard for dose …
treatment planning system on … Monte Carlo (MC) algorithms are the gold standard for dose …
Treatment plan verification: a review on the comparison of dose distributions
S Diamantopoulos, K Platoni, G Patatoukas… - Physica Medica, 2019 - Elsevier
… dosimetric systems … verification procedure comes down to a dose distribution comparison:
Machine-delivered (reference) versus calculated by a Treatment Planning System-TPS dose …
Machine-delivered (reference) versus calculated by a Treatment Planning System-TPS dose …