Characterizing reflux on high resolution esophageal manometry with impedance
A Jehangir, Z Malik, HP Parkman - BMC gastroenterology, 2022 - Springer
… reflux monitoring was performed using Bravo™ Reflux Capsule … testing and ambulatory pH
monitoring with impedance testing… esophageal function testing with esophageal manometry …
monitoring with impedance testing… esophageal function testing with esophageal manometry …
Esophageal Manometry and Esophageal pH Testing
N Vakil - … Gastroesophageal Reflux: A Comprehensive Guide to …, 2020 - Springer
… led to the development of high-resolution manometry using a … consensus conference proposed
new criteria for pH testing in a … are no impedance events, and the distal esophageal pH is …
new criteria for pH testing in a … are no impedance events, and the distal esophageal pH is …
Diagnostic Tests and Interpretations Before Anti-reflux Surgery
BJ Kim - Laparoscopic Antireflux Surgery, 2023 - Springer
… 24-h esophageal pH and impedance test, a representative test … Currently, a system (eg,
Bravo pH probe) is in use to minimize … High-resolution manometric finding of esophagogastric …
Bravo pH probe) is in use to minimize … High-resolution manometric finding of esophagogastric …
[HTML][HTML] Modern evaluation of esophageal function in the gastrointestinal motility laboratory: a narrative review
M Malamood, D Shahsavari… - … of Esophagus, 2023 - aoe.amegroups.org
… often starts with high-resolution esophageal manometry, now … impedance-pH (MII-pH) has
the advantage of measuring … as the Bravo ® capsule, this device is a radiotelemetry capsule …
the advantage of measuring … as the Bravo ® capsule, this device is a radiotelemetry capsule …
Esophageal Testing Using Multichannel Intraluminal Impedance
… Multichannel intraluminal impedance (MII) is a relatively new … offer combined high-resolution
impedance manometry (HRiM) … impedance (MII) parameters of esophageal function testing (…
impedance manometry (HRiM) … impedance (MII) parameters of esophageal function testing (…
ACG clinical guidelines: clinical use of esophageal physiologic testing
CP Gyawali, DA Carlson, JW Chen… - Official journal of the …, 2020 - journals.lww.com
… be assessed using high-resolution impedance manometry (HRIM… use of pH impedance
monitoring over pH monitoring alone … of esophageal function testing to rule out esophageal motor …
monitoring over pH monitoring alone … of esophageal function testing to rule out esophageal motor …
Twenty-four-hour pH metry alone is inferior to additional impedance monitoring in the diagnosis of gastroesophageal reflux disease, particularly in presence of …
UC Ghoshal, SN Biswas, A Elhence, B Fatima… - Indian Journal of …, 2023 - Springer
… esophageal pH monitoring alone (both catheter-based and Bravo capsule) compared to
24-hour impedance monitoring … had to undergo high-resolution esophageal manometry using a …
24-hour impedance monitoring … had to undergo high-resolution esophageal manometry using a …
A SIGE-SINGEM-AIGO technical review on the clinical use of esophageal reflux monitoring
E Savarino, M Frazzoni, E Marabotto, P Zentilin… - Digestive and Liver …, 2020 - Elsevier
… of impedance-pH monitoring and wireless pH capsule, have … application of high resolution
manometry (HRM) has introduced new … PH testing with Bravo system is generally performed in …
manometry (HRM) has introduced new … PH testing with Bravo system is generally performed in …
Esophageal Function Testing for Gastroesophageal Reflux Disease
I Kristo, M Nikolic, SF Schoppmann - Multidisciplinary Management of …, 2021 - Springer
… of high-resolution manometry (HRM) and esophageal … Nevertheless, adding impedance
to pH monitoring improves … Explanatory, persisting GERD and new onset symptoms like …
to pH monitoring improves … Explanatory, persisting GERD and new onset symptoms like …
[HTML][HTML] Improving the diagnostic yield of high-resolution esophageal manometry for GERD: The “straight leg-raise” international study
S Siboni, I Kristo, BD Rogers, N De Bortoli… - Clinical …, 2023 - Elsevier
… , esophageal function tests performed for persistent GERD symptoms, HRM and wireless
pH-study or catheter pH-impedance … The wireless pH-study capsule (BRAVO) was placed 6 cm …
pH-study or catheter pH-impedance … The wireless pH-study capsule (BRAVO) was placed 6 cm …