Feasibility of multiple-view myocardial perfusion MRI using radial simultaneous multi-slice acquisitions

YE Tian, J Mendes, A Pedgaonkar, M Ibrahim… - PLoS …, 2019 - journals.plos.org
… The 90 saturation recovery (SR) pulse was optimized by using … parameters were chosen
empirically by visual evaluation. … automatically selected the left and right ventricles from the pre-…

Simultaneous multislice cardiac cine with Fourier‐encoded self‐calibration at 7 Tesla

S Rapacchi, T Troalen, Z Bentatou… - Magnetic …, 2019 - Wiley Online Library
… at 7T with simultaneous multi-slice (SMS) acquisition.3-5 SMS … Bullseye plots of quality
assessment of myocardium wall … optimization can certainly improve the B 1+ field in the heart,22 …

The dysfunctional right ventricle: the importance of multi-modality imaging

E Surkova, B Cosyns, B Gerber, A Gimelli… - European Heart …, 2022 - academic.oup.com
… other parameters of RV function for dedicated RV assessment (… The multi-slice view is useful
during data acquisition to … can also be used for assessment of RV wall motion abnormalities. …

Quantitative myocardial perfusion with a hybrid 2D simultaneous multi-slice sequence

Q Huang, Y Tian, J Mendes, R Ranjan, G Adluru… - Magnetic resonance …, 2023 - Elsevier
… These images are commonly used for qualitative assessment of myocardial perfusion since
acquisition include the ability to retrospectively reconstruct an accurate AIF and optimized

Real-time spiral CMR is superior to conventional segmented Cine-imaging for left-ventricular functional assessment in patients with arrhythmia

N Nita, J Kersten, A Pott, F Weber, T Tesfay… - Journal of Clinical …, 2022 - mdpi.com
… : Standard cine CMR was performed using a multi-slice b-… and real-time acquisitions for all
parameters. No proportional … sequence should be further optimized in future larger studies. …

Assessment of the Right Ventricle

D Muraru, ML de Alcantara, E Surkova… - Textbook of Three …, 2019 - Springer
… The acquisition of an optimal RV 3D data set is more … If the 3DE system does not allow
for multi-slice display in real … values to grade the severity of right ventricular dysfunction …

Simultaneous multislice steady‐state free precession myocardial perfusion with full left ventricular coverage and high resolution at 1.5 T

S McElroy, G Ferrazzi, MS Nazir… - Magnetic …, 2022 - Wiley Online Library
… Simultaneous multi-slice (SMS) is another technique used for … the acquisition of nine slices
to achieve full left ventricular … empirically optimized to 0.0001, 0.005, and 18 respectively. …

Multi-Slice Radiomic Analysis of Apparent Diffusion Coefficient Metrics Improves Evaluation of Brain Alterations in Neonates With Congenital Heart Diseases

M Zhu, D Zhao, Y Wang, Q Zhou, S Wang, X Mo… - Frontiers in …, 2020 - frontiersin.org
… ADC images were acquired from 60 neonates with echocardiographically confirmed non-…
optimal technique should be determined based on individual patient needs in clinical settings. …

Whole‐heart, ungated, free‐breathing, cardiac‐phase‐resolved myocardial perfusion MRI by using continuous radial interleaved simultaneous multislice acquisitions …

Y Tian, J Mendes, B Wilson, A Ross… - Magnetic resonance …, 2020 - Wiley Online Library
… quality for both gated and ungated acquisitions. However, … whole-heart myocardial perfusion
assessments at multiple … found that once these parameters were optimized for several …

Automated quantification of cardiac short-axis multi-slice CT images for assessment of left ventricular global function

BL der Geest, J Reiber - spiedigitallibrary.org
… Firstly, the left and right ventricular (RV) bloodpools are … Temporal resolution of the acquired
data was sufficient to reconstruct … the optimal values for the segmentation parameters. Thus, …