Plug-and-Play Oxygen Auto-flow Regulator for Low Flow Oxygen Therapy: A Prototype Development

M Balasubramanian, AB Pattaje… - 2022 IEEE …, 2022 - ieeexplore.ieee.org
oxygen tank, pressure regulator and specialized oxygen … based oxygen flow controller suitable
for low flow oxygen therapyOximetry feedback flow control simulation for oxygen therapy.…

Automated Oxygen Blender for Regulation of Oxygen Saturation in Hypoxia Patient

S Anikhindi, S Patil, P Kaushal - Communication and Intelligent Systems …, 2022 - Springer
feedback control system was simulated at different oxygenoximeter to maintain a target SpO
2 of 91% by regulating the … compared to the fixed flow rate long-term oxygen therapy (LTOT)…

Automated oxygen control in preterm infants, how does it work and what to expect: a narrative review

HH Salverda, SJE Cramer, RSGM Witlox… - Archives of Disease in …, 2021 - fn.bmj.com
use oxygen saturation as measured by pulse oximetry (SpO … reviews comparing AOC with
manual titration of oxygen in preterm infants receiving respiratory support and oxygen therapy. …

A randomized controlled trial of oxygen therapy for patients who do not respond to upper airway surgery for obstructive sleep apnea

SA Joosten, M Tan, AM Wong, SA Landry… - Journal of Clinical …, 2021 - jcsm.aasm.org
… stability/instability of a feedback loop system. In a ventilatory … plethysmography bands,
and fingertip pulse oximetry. … Grael amplifier and a wall-mounted oxygen/air flow regulator. …

Efficiency of different flows for apneic oxygenation when using high flow nasal oxygen application–a technical simulation

WA Wetsch, H Herff, DC Schroeder, D Sander… - BMC …, 2021 - Springer
… a paramagnetic oximeter that was … flow nasal oxygen therapy in COVID-19 patients at the
beginning of the pandemic. Thus, the lowest possible air flow that maintains adequate oxygen

Dose variability of supplemental oxygen therapy with open patient interfaces based on in vitro measurements using a physiologically realistic upper airway model

I Katz, J Chen, K Duong, K Zhu, M Pichelin… - Respiratory …, 2019 - Springer
… rate due to variation in simulated breathing pattern. Among the … oxygen cylinder through a
calibrated mass flow controller (… The oxygen saturation should be checked by pulse oximetry in …

Clinical Evaluation of an Automatic Oxygen Control System for Premature Infants Receiving High-Flow Nasal Cannula for Respiratory Support: A Pilot Study

X Hou, A Faqeeh, R Amjad… - Journal of Medical …, 2022 - asmedigitalcollection.asme.org
feedback measurements to determine the desired FiO 2 . … Simulation results showed that this
controller could achieve a … measurements of oxygen saturation by use of the pulse oximeter, …

Oxygen Flow Meter Automation Design Based on SpO2 Levels

A Andrian, MR Mak'ruf… - Jurnal …, 2020 - teknokes.poltekkesdepkes-sby.ac.id
… a reference for administering oxygen therapy (oxygenation) to … nilai acak dikalibrasikan
dengan simulator SpO2 tertentu. … bahwa dengan menggunakan pulse oximeter untuk memantau …

Analysis of parameters affecting blood oxygen saturation and modeling of fuzzy logic system for inspired oxygen prediction

S Radhakrishnan, SG Nair, J Isaac - Computer methods and programs in …, 2019 - Elsevier
… [3] used a state feedback control scheme to regulate the concentration of … inspired oxygen
prediction using fuzzy logic controller by combining the real time values of pulse oximetry with …

Feasibility and efficacy of pulsed-dose oxygen delivery during noninvasive ventilation

LL Li, HY Yang, H Jin, B Dai, Y Peng, W Tan - Respiratory Care, 2020 - rc.rcjournal.com
… 15 h of oxygen therapy a day during home oxygen therapy, 14 the … oximetry because it is
difficult to determine which oxygen … In this study, we used the simulated lung to mimic patients …