Quantification of liver fat content with CT and MRI: state of the art
… CT is important for the detection and quantification of … state of the art for liver fat quantification
using CT and MRI, as well as … -of-the-art liver fat quantification using CT and MRI, including …
using CT and MRI, as well as … -of-the-art liver fat quantification using CT and MRI, including …
Percentage fat fraction in magnetic resonance imaging: upgrading the osteoporosis-detecting parameter
R Chang, X Ma, Y Jiang, D Huang, X Chen… - BMC Medical …, 2020 - Springer
… We proposed that FF% played a crucial role in MRI-based OP … MRI results are correlated
with BMD values and provide the … [25], while QCT and MRI can image and quantify the three-…
with BMD values and provide the … [25], while QCT and MRI can image and quantify the three-…
3D chemical shift‐encoded MRI for volume and composition quantification of abdominal adipose tissue during an overfeeding protocol in healthy volunteers
A Nemeth, B Segrestin, B Leporq… - … Resonance Imaging, 2019 - Wiley Online Library
… body fat. To be more accurate, some imaging modalities like magnetic resonance imaging
(MRI… of patients, whereas MRI allows the measurement of fat volumes without any known short…
(MRI… of patients, whereas MRI allows the measurement of fat volumes without any known short…
Quantification of liver, subcutaneous, and visceral adipose tissues by MRI before and after bariatric surgery
… the individual distribution of body fat prior to a … organ volume, which provided us with more
representative data. In the present study, the reproducibility of fat quantification by use of MRI …
representative data. In the present study, the reproducibility of fat quantification by use of MRI …
[HTML][HTML] MRI in the assessment of adipose tissues and muscle composition: how to use it
… , allowing to accurately quantify fat content in any image voxel through fat-fraction maps … to
its respective fat-percentage (39). This technique is most widely used for quantification of liver …
its respective fat-percentage (39). This technique is most widely used for quantification of liver …
Liver fat content measurement with quantitative CT validated against MRI proton density fat fraction: a prospective study of 400 healthy volunteers
Z Guo, GM Blake, K Li, W Liang, W Zhang, Y Zhang… - Radiology, 2020 - pubs.rsna.org
… MRI quantify liver fat directly in terms of the proton density fat … strength from fat to the total
signal from fat and water (11,16). … of soft tissue composition in nonosseous tissues such as the …
signal from fat and water (11,16). … of soft tissue composition in nonosseous tissues such as the …
Reproducibility and repeatability of MRI‐based body composition analysis
… MRI is increasingly frequently being used for body composition analysis and is today …
for compartmental quantification of adipose tissue 20 and muscle volumes. MRI-based body …
for compartmental quantification of adipose tissue 20 and muscle volumes. MRI-based body …
Quantitative 1H MRI and MRS of fatty acid composition
P Peterson, L Trinh, S Månsson - Magnetic Resonance in …, 2021 - Wiley Online Library
… both MRI and MRS differ, making comparisons between different techniques difficult. The
aim of this paper is to review MRS- and MRI-based methods for in vivo quantification … body fat …
aim of this paper is to review MRS- and MRI-based methods for in vivo quantification … body fat …
Liver fat quantification: where do we stand?
J Starekova, SB Reeder - Abdominal Radiology, 2020 - Springer
… quantifying liver fat, chemical-shift-encoded MRI (CSE-MRI)-based proton density fat-…
methods are FDA approved on all major MRI vendors, for the purpose of quantifying tissue fat …
methods are FDA approved on all major MRI vendors, for the purpose of quantifying tissue fat …
Accurate fatty acid composition estimation of adipose tissue in the abdomen based on bipolar multi‐echo MRI
M Schneider, G Janas, F Lugauer… - Magnetic resonance …, 2019 - Wiley Online Library
… Second, the proposed MRI-based FAC quantification method estimates the relative degree
of saturation based on the number of overall fatty acid occurrences, whereas the relative …
of saturation based on the number of overall fatty acid occurrences, whereas the relative …