Quantitative assessment of two-and three-dimensional transthoracic and two-dimensional transesophageal echocardiography, computed tomography, and magnetic …
RC Fries, SG Gordon, AB Saunders, MW Miller… - Journal of Veterinary …, 2019 - Elsevier
… Left ventricular EF and LA size via CTA compared best with CMR and RV and RA volumes
were … Each dog had five complete studies performed by each investigator over 2–7 days. The …
were … Each dog had five complete studies performed by each investigator over 2–7 days. The …
Accuracy of cardiac functional parameters measured from gated radionuclide myocardial perfusion imaging in mice
… Quantitative cardiac contractile function assessment is the primary indicator of disease
progression and therapeutic efficacy in small animals… of quantitative left ventricular function …
progression and therapeutic efficacy in small animals… of quantitative left ventricular function …
Assessment of left atrial volume in dogs: comparisons of two-dimensional and real-time three-dimensional echocardiography with ECG-gated multidetector computed …
J Bouvard, F Thierry, GJ Culshaw, T Schwarz… - Journal of Veterinary …, 2019 - Elsevier
… algorithm (method of disk [MOD]), which is similar to the method for measuring left ventricular
volume… were obtained and averaged for each dog from three representative cardiac cycles. …
volume… were obtained and averaged for each dog from three representative cardiac cycles. …
Towards quantitative small-animal imaging on hybrid PET/CT and PET/MRI systems
… software solutions dedicated for quantitative studies in small-animals has spurred academic
… for higher image quality and more accurate quantitative analysis. Image quality achieved in …
… for higher image quality and more accurate quantitative analysis. Image quality achieved in …
Assessment of left and right ventricular functional parameters using dynamic dual-tracer [13N] NH3 and [18F] FDG PET/MRI
… , mostly through congestive heart failure and left ventricular systolic dysfunction. Actually,
due to … Quantitative analysis of both FDG and NH 3 PET data for obtaining the left ventricular …
due to … Quantitative analysis of both FDG and NH 3 PET data for obtaining the left ventricular …
… glucose uptake from dynamic FDG PET images of rat heart in vivo: comparative study between the inferior vena cava and the left ventricular blood pool with spill over …
… function from the inferior vena cava (IVC) with partial volume (PV) corrections and compare
to that obtained from the left ventricular … in quantitative myocardial PET studies J. Nucl. Med. …
to that obtained from the left ventricular … in quantitative myocardial PET studies J. Nucl. Med. …
Prognostic value of quantitative metrics from positron emission tomography in ischemic heart failure
DC Benz, PA Kaufmann, E von Felten, G Benetos… - Cardiovascular …, 2021 - jacc.org
… analysis of a single-center cohort, quantitative PET metrics of myocardial blood flow all
improved risk stratification in patients with ischemic heart … Left ventricular (LV) dysfunction due to …
improved risk stratification in patients with ischemic heart … Left ventricular (LV) dysfunction due to …
… standardization of echocardiography for the evaluation of left ventricular function in adult rodents: a position paper of the ESC Working Group on Myocardial Function
S Zacchigna, A Paldino, I Falcão-Pires… - Cardiovascular …, 2021 - academic.oup.com
… in small animals. This position paper focuses on the appropriate acquisition and analysis of
… The efficacy of new therapeutics in small animal models is key for their further application in …
… The efficacy of new therapeutics in small animal models is key for their further application in …
EANM procedural guidelines for PET/CT quantitative myocardial perfusion imaging
R Sciagrà, M Lubberink, F Hyafil, A Saraste… - European Journal of …, 2021 - Springer
… quantitative assessment of myocardial perfusion. Nevertheless, the acquisition and analysis
of quantitative PET … , and blood volume, and even left ventricle (LV) volumes and ejection …
of quantitative PET … , and blood volume, and even left ventricle (LV) volumes and ejection …
Quantification of PET myocardial blood flow
M Pelletier-Galarneau, P Martineau… - Current Cardiology …, 2019 - Springer
… Briefly, a left ventricular (LV) chamber time activity curve (… assessment, LV systolic function,
and semi-quantitative measurements of ischemia and scar. Interestingly, the risk of cardiac …
and semi-quantitative measurements of ischemia and scar. Interestingly, the risk of cardiac …