Visualization of low-level gamma radiation sources using a low-cost, high-sensitivity, omnidirectional compton camera

H Muraishi, R Enomoto, H Katagiri, M Kagaya… - JoVE (Journal of …, 2020 - jove.com
… -level gamma radiation sources in the ambient environment. … Figure 6b shows the total
energy spectra for each period, … portable gamma camera 5 , 27 . The main reasons for such …

The Spid-X gamma camera: A miniature gamma ray integral field spectrometer for nuclear industry applications

R Le Breton, O Limousin, G Daniel, D Diquelou… - Nuclear Instruments and …, 2023 - Elsevier
… of gamma camera developments at CEA/IRFU, made commercially available by industrial
partners. It is designed to have improved spectrometryenvironmental conditions) and the high

Experimental validation of a spectroscopic gamma-ray detector based on a LaBr3 scintillator towards real-time dose monitoring in BNCT

A Caracciolo, D Di Vita, L Buonanno… - Nuclear Instruments and …, 2022 - Elsevier
… The highest values are around 25 keV and correspond to the spectra of the Set of … in the
sample, due to the different irradiation environment at the TRIGA MARK II with respect to the …

Radiation imaging using an integrated Radiation Imaging System based on a compact Compton camera under unit 1/2 exhaust stack of Fukushima Daiichi Nuclear …

Y Sato, Y Terasaka - Journal of Nuclear Science and Technology, 2022 - Taylor & Francis
… -type gamma camera and omni-directional Compton camera … measurements in a high dose
rate environment, such as the … The energy spectra of the coincidence events between the …

Development of a hybrid gamma camera based on Timepix3 for nuclear industry applications

G Amoyal, V Schoepff, F Carrel, M Michel… - Nuclear Instruments and …, 2021 - Elsevier
spectrometric performances of the Compton gamma camera. … develop a hybrid gamma
camera prototype combining coded-… In the case of an unknown environment, it is not possible to …

Development of an MPPC-based gamma-ray detector onboard a radiation source imager under high-dose environments and initial performance results

T Mizuno, M Arimoto, D Sato, K Yoshiura… - Nuclear Instruments and …, 2023 - Elsevier
… The two-dimensional sensor array developed in this study can obtain incident gamma-ray …
We have obtained the spectra by using several reference radioactive sources for gamma-…

[HTML][HTML] … of an omnidirectional Compton camera using CaF2 (Eu) scintillators to visualize gamma rays with energy below 250 keV for radioactive environmental …

H Katagiri, N Narita, R Enomoto, H Muraishi… - Nuclear Instruments and …, 2021 - Elsevier
… Compton camera for radioactive environmental monitoring which can visualize gamma
rays with energy below 250 keV emitted from various radiopharmaceuticals used in nuclear …

Medical gamma cameras in radiological emergency preparedness: determination of calibration factors and MDA for the GE Discovery NM/CT 670 Pro

M Hjellström, M Isaksson - Journal of Radiological Protection, 2023 - iopscience.iop.org
… In emergency situations following the release of radionuclides into the environment, so-called …
the spectra were retrieved from the gamma camera as raw data from the gamma camera

[HTML][HTML] Miniaturised low-cost gamma scanning platform for contamination identification, localisation and characterisation: A new instrument in the decommissioning …

Y Verbelen, PG Martin, K Ahmad, S Kaluvan, TB Scott - Sensors, 2021 - mdpi.com
… if necessary) gamma camera capable of generating a PCD in nuclear decommissioning
environments. … As discussed previously, the spectral data is then used to calculate a dose map …

Calibration of a SPECT-CT gamma camera with child and adult thyroid-neck phantoms for in vivo monitoring of radioiodine in the exposed population in case of …

JF Navarro, B Pérez, MA López, R Plaza, Z Aza… - Radiation Physics and …, 2020 - Elsevier
gamma spectrometry at Whole Body Counters (WBC) is the recommended technique, but it
is difficult to manage in case of a large … be released to the environment with the subsequent …