Optical coherence tomography (OCT): principle and technical realization
S Aumann, S Donner, J Fischer, F Müller - … imaging in microscopy and …, 2019 - Springer
… methods are introduced and compared regarding their properties like sensitivity, imaging …
Regardless of the technical realization, axial resolution and imaging range of an OCT system …
Regardless of the technical realization, axial resolution and imaging range of an OCT system …
[HTML][HTML] A deep learning system for automated angle-closure detection in anterior segment optical coherence tomography images
… on the anterior segment optical coherence tomography data set against clinicians' grading
of anterior segment optical coherence tomography images as the reference standard. The …
of anterior segment optical coherence tomography images as the reference standard. The …
[图书][B] Optical coherence tomography of ocular diseases
… In vivo retinal imaging by optical coherence tomography. Optics Letters. 1993;113:1019.) …
Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence …
Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence …
En face optical coherence tomography: a technology review
RA Leitgeb - Biomedical optics express, 2019 - opg.optica.org
… coherent depth gating. The first en face OCT system was reported by Izatt el al. for optical
coherence … Later, Podoleanu et al. were able to image the human retina in-vivo with en face TS …
coherence … Later, Podoleanu et al. were able to image the human retina in-vivo with en face TS …
High-resolution in-vivo human retinal imaging using full-field OCT with optical stabilization of axial motion
P Mecê, J Scholler, K Groux, C Boccara - Biomedical optics express, 2020 - opg.optica.org
… Optical Coherence Tomography (OCT) has become a gold … imaging system with optical
stabilization of axial motion. This system was made possible by combining the FF-OCT system …
stabilization of axial motion. This system was made possible by combining the FF-OCT system …
Deep learning-based super-resolution in coherent imaging systems
… and self-interference terms 4 ) in both of the coherent imaging systems that were used in
this work. To perform this, an initial zero-phase was assigned to the intensity/amplitude …
this work. To perform this, an initial zero-phase was assigned to the intensity/amplitude …
Real-time high-resolution mid-infrared optical coherence tomography
… -domain optical coherence tomography system operating at a … The system produces
two-dimensional cross-sectional images in … The images produced by the mid-infrared system are …
two-dimensional cross-sectional images in … The images produced by the mid-infrared system are …
Optical coherence tomography in coronary atherosclerosis assessment and intervention
M Araki, SJ Park, HL Dauerman, S Uemura… - Nature Reviews …, 2022 - nature.com
… Optical coherence tomography (OCT) is an imaging technology used to evaluate the
microstructure of coronary arteries. The axial resolution of OCT is approximately 10–15 µm (ref. ), …
microstructure of coronary arteries. The axial resolution of OCT is approximately 10–15 µm (ref. ), …
APOSTEL 2.0 recommendations for reporting quantitative optical coherence tomography studies
A Aytulun, A Cruz-Herranz, O Aktas, LJ Balcer, L Balk… - Neurology, 2021 - AAN Enterprises
… The modified Delphi method is described as a consensus-building process. We contacted
892 authors of quantitative (optical coherence tomography [OCT]) studies identified by …
892 authors of quantitative (optical coherence tomography [OCT]) studies identified by …
Quadruple ultrasound, photoacoustic, optical coherence, and fluorescence fusion imaging with a transparent ultrasound transducer
… imaging system that seamlessly integrates … imaging, photoacoustic imaging, optical coherence
tomography, and fluorescence imaging, and we demonstrate the system’s use in imaging …
tomography, and fluorescence imaging, and we demonstrate the system’s use in imaging …