Estimating central systolic blood pressure during oscillometric determination of blood pressure: proof of concept and validation by comparison with intra-aortic …

SE Brett, A Guilcher, B Clapp… - Blood pressure …, 2012 - journals.lww.com
Objectives Central systolic blood pressure is usually estimated by transformation of a
peripheral arterial waveform obtained by tonometry and calibrated from conventional …

Evaluation of a novel sphygmomanometer, which estimates central aortic blood pressure from analysis of brachial artery suprasystolic pressure waves

ACW Lin, A Lowe, K Sidhu, W Harrison… - Journal of …, 2012 - journals.lww.com
Background: Central arterial pressure is a better predictor of adverse cardiovascular
outcomes than brachial blood pressure, but noninvasive measurement by applanation …

Noninvasive measurement of central vascular pressures with arterial tonometry: clinical revival of the pulse pressure waveform?

MR Nelson, J Stepanek, M Cevette, M Covalciuc… - Mayo Clinic …, 2010 - Elsevier
The arterial pulse has historically been an essential source of information in the clinical
assessment of health. With current sphygmomanometric and oscillometric devices, only the …

Mean arterial pressure estimated by brachial pulse wave analysis and comparison with currently used algorithms

A Grillo, P Salvi, G Furlanis, C Baldi… - Journal of …, 2020 - journals.lww.com
Objective: Mean arterial pressure (MAP) is usually calculated by adding one-third of pulse
pressure (PP) to DBP. This formula assumes that the average value of pulse waveform is …

Electrode optimization for bioimpedance based central aortic blood pressure estimation

M Metshein, H Kõiv, P Annus, M Min - … Engineering 2018: June 3-8, 2018 …, 2019 - Springer
Evidence suggests that assessment of the central aortic pressure (CAP) of blood is vital for
accurate detection of cardiovascular events and for making treatment decisions. Direct CAP …

Pulse pressure amplification, pressure waveform calibration and clinical applications

D Agnoletti, Y Zhang, P Salvi, C Borghi, J Topouchian… - Atherosclerosis, 2012 - Elsevier
Obtaining pulse pressure non-invasively from applanation tonometry requires the calibration
of pressure waveform with brachial systolic and diastolic blood pressure. In the literature …

P8. 08 A Method Comparison of Central Blood Pressure Measurements by Pulsecor and Sphygmocor Devices

CM Park, K March, AK Ghosh, T Tillin, J Mayet, A Lowe… - Artery research, 2010 - Springer
Background Estimated aortic (or central) systolic pressure (cSBP) differs from peripheral
pressure and may be a better predictor of cardiovascular events. SphygmoCor®(AtCor …

Automated office blood pressure—incorporating SPRINT into clinical practice

MG Myers - American Journal of Hypertension, 2017 - academic.oup.com
The Systolic Blood Pressure Intervention Trial (SPRINT) used the automated office blood
pressure (AOBP) technique for determining the BP status of patients, including BP criteria for …

Evaluation of a brachial cuff and suprasystolic waveform algorithm method to noninvasively derive central blood pressure

BT Costello, MG Schultz, JA Black… - American journal of …, 2015 - academic.oup.com
BACKGROUND Central blood pressure (BP) can be estimated noninvasively by analyzing
brachial artery waveforms. In this study, our aim was to assess the validity of a brachial cuff …

The use of ambulatory tonometric radial arterial wave capture to measure ambulatory blood pressure: the validation of a novel wrist-bound device in adults

D Nair, SY Tan, HW Gan, SF Lim, J Tan… - Journal of human …, 2008 - nature.com
Although ambulatory blood pressure (BP) monitoring provides a better guide to the
management of hypertension, 1–4 these devices are cumbersome and inconvenient, and …