A proposal for a reconstruction (derivation) of V1-V6 using leads I, II, and a “sternal notch lead”: A solution to the problem of non-reproducibility of precordial leads in …

JE Madias - Journal of Electrocardiology, 2019 - Elsevier
Variation of the amplitude and morphology of V1-V6 leads in serial ECGs, due to variation in
the placement of V1-V6 recording electrodes, and the noncompliance in placing the V1-V6 …

A Proposal for a 9‐Lead Electrocardiogram Recorded via the Wilson's Central Terminal

JE Madias - Annals of Noninvasive Electrocardiology, 2013 - Wiley Online Library
The author argues that the universally employed 12‐lead standard electrocardiogram (ECG)
which consists of a conglomerate of 3 bipolar limb leads, 6 quasi‐unipolar precordial leads …

How many electrodes and where? A" poldermodel" for electrocardiography

JA Kors, G van Herpen - Journal of electrocardiology, 2002 - search.proquest.com
It is known that body surface potential maps (BSPMs) contain diagnostic information not
easily retrieved from the standard 12-lead electrocardiogram (ECG). Alternate lead sets that …

The 13th multiuse ECG lead: Shouldn't we use it more often, and on the same hard copy or computer screen, as the other 12 leads?

JE Madias - Journal of electrocardiology, 2004 - Elsevier
Although the ECG diagnosis of cardiac pathology is well served by the employment of the
standard 12 ECG leads, an occasional need arises that additional leads might provide a …

A comparative analysis of several corrected vectorcardiographic leads

DA BRODY, RC ARZBAECHER, HA Phillips - Circulation, 1964 - Am Heart Assoc
The sensitivity of several corrected vectorcardiographic leads to dipolar, quadripolar, and
octapolar components of the equivalent cardiac generator was determined in an electrically …

Optimal placement of dual chest leads for deriving 12-lead/18-lead electrocardiograms and vectorcardiograms

JY Wang, JW Warren… - Computers in Cardiology …, 2005 - ieeexplore.ieee.org
Our aim was to develop and evaluate transformations for deriving standard 12-lead ECG, 18-
lead ECG (with added V7-V9, V3R-V5R), and Frank VCG from lead sets using 3 limb …

[引用][C] Evaluation of Synthesized Standard 12 Leads and Frank Vector Leads1

HK Wolf, PM Rautaharju, VC Unite, J Stewart - Electrocardiology, 1976 - karger.com
In recent years, there has been a prominent trend to three-channel ECG recording whereby
the standard 12-lead ECGs are sequenced through automatic switching in four sets of three …

Compromise in vectorcardiography Displacement of electrodes as a means of adapting one lead system to another

HC Burger, AGW Van Brummelen, G Van Herpen - American Heart Journal, 1961 - Elsevier
An attempt was made to improve the agreement between the Schmitt SVEC-II and the
burger B 1 W 4 ″systems by shifting the ventral and dorsal electrodes of the SVEC-II system …

What's old, what's new-in nonarrhythmia clinical electrocardiography

J Liebman - Journal of Electrocardiology, 2004 - search.proquest.com
Fig. 1. The “Burger Scalane Triangle." Lead vectors as determined from a torso model that
includes spine and lungs. The triangle does not actually lie in the frontal plane, since V1 …

64 EINTHOVEN'S TRIANGLE: LEAD ERRORS AND AN ALGORITHM FOR SOLUTION

FT Bennett, KR Bennett… - Journal of Investigative …, 2005 - search.proquest.com
The three bipolar leads (I, II, and III) of the 12-lead electrocardiogram are subject to technical
errors that not only confound interpretation but may lead to faulty clinical actions. And while …