Quality assurance of a 50-kV radiotherapy unit using EBT3 GafChromic film: a feasibility study

F Steenbeke, T Gevaert, K Tournel… - … in cancer research …, 2016 - journals.sagepub.com
Purpose: Radiochromic EBT3 film is gaining acceptance as a valuable dosimetry system for
high-energy photon beams. The advantages of these films over other dosimetry systems are …

Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry

R Moylan, T Aland, T Kairn - … physical & engineering sciences in medicine, 2013 - Springer
Radiochromic film has the potential to provide accurate in vivo dosimetry measurements.
However, it is not known whether small film pieces can still provide accurate dosimetric …

Radiochromic film dosimetry: considerations on precision and accuracy for EBT2 and EBT3 type films

R Dreindl, D Georg, M Stock - Zeitschrift für Medizinische Physik, 2014 - Elsevier
Gafchromic® EBT2 film is a widely used dosimetric tool for quality assurance in radiation
therapy. In 2012 EBT3 was presented as a replacement for EBT2 films. The symmetric …

Application of Gafchromic EBT2 film for intraoperative radiation therapy quality assurance

M Robatjazi, SR Mahdavi, A Takavr, HR Baghani - Physica Medica, 2015 - Elsevier
Purpose Intraoperative radiation therapy (IORT) using electron beam is commonly done by
mobile dedicated linacs that have a variable range of electron energies. This paper focuses …

Energy dependence of the Gafchromic EBT4 film: Dose‐response curves for 70 kV, 6 MV, 6 MV FFF, 10 MV FFF, and 15 MV x‐ray beams

MF Chan, J Park, R Aydin, SB Lim - Medical physics, 2023 - Wiley Online Library
Background EBT4 was newly released for radiotherapy quality assurance to improve the
signal‐to‐noise ratio in radiochromic film dosimetry. It is important to know its dose …

Comparative analysis of dosimetric uncertainty using Gafchromic™ EBT4 and EBT3 films in radiochromic film dosimetry

Y Akdeniz - Radiation Physics and Chemistry, 2024 - Elsevier
Advancements in radiotherapy dosimetry aim to enhance precision and accuracy, with
Gafchromic™ EBT4 film emerging as a promising tool. However, its performance compared …

Evaluation of Gafchromic® EBT3 films characteristics in therapy photon, electron and proton beams

J Sorriaux, A Kacperek, S Rossomme, JA Lee… - Physica Medica, 2013 - Elsevier
Purpose To evaluate the uncertainties and characteristics of radiochromic film-based
dosimetry system using the EBT3 model Gafchromic® film in therapy photon, electron and …

Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance

T Aland, T Kairn, J Kenny - … physical & engineering sciences in medicine, 2011 - Springer
This study examines the dosimetric accuracy of Gafchromic EBT2 model radiochromic film
for use in radiotherapy quality assurance. In this study, film was scanned using an Epson …

Radiation dose verification of an X-ray based blood irradiator using EBT3 radiochromic films calibrated using Gamma Knife machine

K Soliman, M Adili, A Alrushoud - Reports of Practical …, 2019 - journals.viamedica.pl
Aim Blood irradiators (BI) initial acceptance testing and routine annual dosimetry checks
require radiation dose measurements in order to comply with regulatory requirements …

Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance

M Fuss, E Sturtewagen, C De Wagter… - Physics in Medicine & …, 2007 - iopscience.iop.org
The suitability of radiochromic EBT film was studied for high-precision clinical quality
assurance (QA) by identifying the dose response for a wide range of irradiation parameters …