[PDF][PDF] Performance evaluation of a whole-body PET scanner using the NEMA protocol

G Brix, J Zaers, LE Adam, ME Bellemann… - Journal of Nuclear …, 1997 - Soc Nuclear Med
The scanner consists of four rings of 72 bismuth germanate block detectors each, covering
an axial field of view of 15.5 cm with a patient port of 56.2 cm. A single block detector is …

[PDF][PDF] Performance characteristics of a whole-body PET scanner

TR DeGrado, TG Turkington, JJ Williams… - Journal of Nuclear …, 1994 - Soc Nuclear Med
MATERIALS AND METhODS System Description The newly designed PET scanner
(Advance, General Electric Medical Systems, Milwaukee, WI) has 12,096 bismuth …

Performance characteristics of a newly developed PET/CT scanner using NEMA standards in 2D and 3D modes

O Mawlawi, DA Podoloff, S Kohlmyer… - Journal of Nuclear …, 2004 - Soc Nuclear Med
This study evaluates the 2-dimensional (2D) and 3-dimensional (3D) performance
characteristics of a newly developed PET/CT scanner using the National Electrical …

NEMA NU 4-2008 comparison of preclinical PET imaging systems

AL Goertzen, Q Bao, M Bergeron… - Journal of nuclear …, 2012 - Soc Nuclear Med
The National Electrical Manufacturers Association (NEMA) standard NU 4-2008 for
performance measurements of small-animal tomographs was recently published. Before this …

Performance evaluation of a large axial field-of-view PET scanner: SET-2400W

T Fujiwara, S Watanuki, S Yamamoto, M Miyake… - Annals of nuclear …, 1997 - Springer
The SET-2400W is a newly designed whole-body PET scanner with a large axial field of
view (20 cm). Its physical performance was investigated and evaluated. The scanner …

Performance of a whole-body PET scanner using curve-plate NaI (Tl) detectors

LE Adam, JS Karp… - Journal of Nuclear …, 2001 - Soc Nuclear Med
A whole-body PET scanner, without interplane septa, has been designed to achieve high
performance in clinical applications. The C-PET scanner, an advancement of the PENN PET …

A prototype PET scanner with DOI-encoding detectors

Y Yang, Y Wu, J Qi, SS James, H Du… - Journal of Nuclear …, 2008 - Soc Nuclear Med
Detectors with depth-encoding allow a PET scanner to simultaneously achieve high
sensitivity and high spatial resolution. Methods: A prototype PET scanner, consisting of …

Estimating the NEMA characteristics of the J-PET tomograph using the GATE package

P Kowalski, W Wiślicki, RY Shopa… - Physics in Medicine …, 2018 - iopscience.iop.org
A novel whole-body positron emission tomography (PET) system based on plastic
scintillators is developed by the J-PET Collaboration. It consists of plastic scintillator strips …

Performance evaluation of the new whole-body PET/CT scanner: Discovery ST

V Bettinardi, M Danna, A Savi, M Lecchi… - European journal of …, 2004 - Springer
Characterisation of the physical performance of the new integrated PET/CT system
Discovery ST (GE Medical Systems) has been performed following the NEMA NU 2-1994 (N …

Simulating NEMA characteristics of the modular total-body J-PET scanner—an economic total-body PET from plastic scintillators

P Moskal, P Kowalski, RY Shopa… - Physics in Medicine …, 2021 - iopscience.iop.org
The purpose of the presented research is estimation of the performance characteristics of
the economic total-body Jagiellonian-PET system (TB-J-PET) constructed from plastic …