An efficient framework for photon Monte Carlo treatment planning

MK Fix, P Manser, D Frei, W Volken… - Physics in Medicine & …, 2007 - iopscience.iop.org
Abstract Currently photon Monte Carlo treatment planning (MCTP) for a patient stored in the
patient database of a treatment planning system (TPS) can usually only be performed using …

[HTML][HTML] Validation of the Swiss Monte Carlo Plan for a static and dynamic 6 MV photon beam

V Magaddino, P Manser, D Frei, W Volken… - … für Medizinische Physik, 2011 - Elsevier
Monte Carlo (MC) based dose calculations can compute dose distributions with an accuracy
surpassing that of conventional algorithms used in radiotherapy, especially in regions of …

Monte Carlo treatment planning for photon and electron beams

N Reynaert, SC Van der Marck, DR Schaart… - Radiation Physics and …, 2007 - Elsevier
During the last few decades, accuracy in photon and electron radiotherapy has increased
substantially. This is partly due to enhanced linear accelerator technology, providing more …

Comparison of Monte Carlo collimator transport methods for photon treatment planning in radiotherapy

D Schmidhalter, P Manser, D Frei, W Volken… - Medical …, 2010 - Wiley Online Library
Purpose: The aim of this work was a Monte Carlo (MC) based investigation of the impact of
different radiation transport methods in collimators of a linear accelerator on photon beam …

Modeling and commissioning of clinical photon beams for Monte Carlo treatment planning

SB Jiang, J Deng, J Li, T Pawlicki, AL Boyer… - The Use of Computers in …, 2000 - Springer
Monte Carlo treatment planning requires accurate beam information as input to generate
accurate dose distributions. The phase space data of a clinical photon beam can be …

Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planning

IJ Chetty, B Curran, JE Cygler, JJ DeMarco… - Medical …, 2007 - Wiley Online Library
The Monte Carlo (MC) method has been shown through many research studies to calculate
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …

Virtual source modelling of photon beams for Monte Carlo based radiation therapy treatment planning

MP Sikora - 2011 - bora.uib.no
Modern radiotherapy (RT) techniques such as stereotactic body radiotherapy (SBRT),
intensitymodulated radiotherapy (IMRT) or volumetric modulated arc therapy (VMAT) carries …

Beam modeling and beam model commissioning for Monte Carlo dose calculation‐based radiation therapy treatment planning: Report of AAPM Task Group 157

CMC Ma, IJ Chetty, J Deng, B Faddegon… - Medical …, 2020 - Wiley Online Library
Dose calculation plays an important role in the accuracy of radiotherapy treatment planning
and beam delivery. The Monte Carlo (MC) method is capable of achieving the highest …

A Monte Carlo dose calculation tool for radiotherapy treatment planning

CM Ma, JS Li, T Pawlicki, SB Jiang… - Physics in Medicine …, 2002 - iopscience.iop.org
A Monte Carlo user code, MCDOSE, has been developed for radiotherapy treatment
planning (RTP) dose calculations. MCDOSE is designed as a dose calculation module …

Validation of a Monte Carlo dose calculation tool for radiotherapy treatment planning

JS Li, T Pawlicki, J Deng, SB Jiang… - Physics in Medicine & …, 2000 - iopscience.iop.org
Abstract A new EGS4/PRESTA Monte Carlo user code, MCDOSE, has been developed as a
routine dose calculation tool for radiotherapy treatment planning. It is suitable for both …