Retentive force variations in three polyamide and a polyetheretherketone denture attachments for implant-supported overdentures: an in vitro study

M Βei, SN Kamalakidis, AL Pissiotis… - The Journal of Prosthetic …, 2023 - Elsevier
Statement of problem The loss in the retentive capability of implant-supported overdenture
attachments has been related to the wear of the retentive inserts. Wear of the abutment …

The service life of implant-retained overdenture attachment systems

MN Pigozzo, MF Mesquita, GEP Henriques… - The Journal of prosthetic …, 2009 - Elsevier
STATEMENT OF PROBLEM: Implant-retained overdentures are a treatment option for
patients who are not satisfied with conventional complete dentures. Although implant …

Evaluation of retention forces and resistance to fatigue of attachment systems for overdentures: plastic and metal components

LC da Fontoura Frasca, PRC Mattia, DM Botega… - Implant …, 2014 - journals.lww.com
Purpose: To compare retention forces of 3 overdenture attachment systems with metal and
plastic components. Materials and Methods: Four samples of each system evaluated (Ball …

Comparative study of four retentive anchor systems for implant supported overdentures–retention force changes

S Bayer, D Steinheuser, M Grüner, L Keilig… - …, 2009 - Wiley Online Library
Objectives: Wear of attachments leads to a loss of retention and potentially reduces the
function of complete dentures. This study evaluated the retention force changes of different …

[PDF][PDF] Comparison between Two Different Attachment Caps Used in Locator Attachments of Implant supported Overdentures (In-Vitro Study)

HEF Haridy, HM El Afandy… - Future Dental …, 2022 - digitalcommons.aaru.edu.jo
Purpose: To compare different retentive cap material used in LOCATOR attachments,
namely the nylon retentive cap versus PEEK retentive caps, and measure the loss of …

In vitro comparison of the retentive properties of ball and locator attachments for implant overdentures.

P Eren Türk, O Geckili, Y Türk… - … Journal of Oral & …, 2014 - search.ebscohost.com
Purpose: To compare the retentive properties of ball and locator attachments during 5,000
insertion-separation cycles, corresponding to approximately 4.5 years of clinical use …

The in vitro effect of different implant angulations and cyclic dislodgement on the retentive properties of an overdenture attachment system

SA Al-Ghafli, KX Michalakis, H Hirayama… - Journal of Prosthetic …, 2009 - thejpd.org
Purpose. The purpose of this in vitro study was to investigate the effect of cyclic
dislodgement on the retention of an overdenture attachment system when 2 implants were …

Retention force and allowable range of the angle of an implant-supported overdenture attachment system using healing screws and a silicone resilient denture liner

T Koike, K Kubo, T Kono, T Ueda, K Sakurai - The Journal of Prosthetic …, 2020 - Elsevier
Statement of problem Changes in the intraoral condition immediately after implant
placement and in patients using fixed prosthetic appliances with implant abutments cause …

Patient satisfaction versus retention of implant overdentures with two attachment systems: A randomized trial

RF de Albuquerque Jr, O Fromentin… - … implant dentistry and …, 2019 - Wiley Online Library
Background Clinical success with mandibular implant overdentures is highly dependent on
a reliable attachment system connecting prosthesis and implants. Purpose To compare the …

Retention and wear of resin matrix attachments for implant overdentures

N Wichmann, M Kern, T Taylor, S Wille… - Journal of the mechanical …, 2020 - Elsevier
Objectives The aim of the present laboratory study was to investigate the retentive properties
and the wear of three different resin matrix attachments for implant overdentures as well as …