Performance characteristics of a newly developed PET/CT scanner using NEMA standards in 2D and 3D modes

O Mawlawi, DA Podoloff, S Kohlmyer… - Journal of Nuclear …, 2004 - Soc Nuclear Med
This study evaluates the 2-dimensional (2D) and 3-dimensional (3D) performance
characteristics of a newly developed PET/CT scanner using the National Electrical …

Performance evaluation of the new whole-body PET/CT scanner: Discovery ST

V Bettinardi, M Danna, A Savi, M Lecchi… - European journal of …, 2004 - Springer
Characterisation of the physical performance of the new integrated PET/CT system
Discovery ST (GE Medical Systems) has been performed following the NEMA NU 2-1994 (N …

[PDF][PDF] Performance characteristics of a whole-body PET scanner

TR DeGrado, TG Turkington, JJ Williams… - Journal of Nuclear …, 1994 - Soc Nuclear Med
MATERIALS AND METhODS System Description The newly designed PET scanner
(Advance, General Electric Medical Systems, Milwaukee, WI) has 12,096 bismuth …

Performance of a whole-body PET scanner using curve-plate NaI (Tl) detectors

LE Adam, JS Karp… - Journal of Nuclear …, 2001 - Soc Nuclear Med
A whole-body PET scanner, without interplane septa, has been designed to achieve high
performance in clinical applications. The C-PET scanner, an advancement of the PENN PET …

Performance evaluation of the FLEX triumph X-PET scanner using the national electrical manufacturers association NU-4 standards

R Prasad, O Ratib, H Zaidi - Journal of Nuclear Medicine, 2010 - Soc Nuclear Med
The purpose of this work was to evaluate the performance characteristics of the preclinical X-
PET subsystem of the FLEX Triumph PET/CT scanner based on the NU 4-2008 standards of …

Performance characteristics of a new 3-dimensional continuous-emission and spiral-transmission high-sensitivity and high-resolution PET camera evaluated with the …

K Matsumoto, K Kitamura, T Mizuta… - Journal of Nuclear …, 2006 - Soc Nuclear Med
The SET-3000 G/X (clinical tomograph with high resolution and a large axial field of view) is
a 3-dimensional (3D)(only) dedicated PET camera with germanium oxyorthosilicate (GSO) …

NEMA NU 2-2001 performance measurements of an LYSO-based PET/CT system in 2D and 3D acquisition modes

BJ Kemp, C Kim, JJ Williams, A Ganin… - Journal of Nuclear …, 2006 - Soc Nuclear Med
The National Electrical Manufacturers Association (NEMA) NU 2-2001 performance
measurements were conducted on the Discovery RX, a whole-body PET/CT system under …

Performance evaluation of the uEXPLORER total-body PET/CT scanner based on NEMA NU 2-2018 with additional tests to characterize PET scanners with a long …

BA Spencer, E Berg, JP Schmall… - Journal of Nuclear …, 2021 - Soc Nuclear Med
The world's first total-body PET scanner with an axial field of view (AFOV) of 194 cm is now
in clinical and research use at our institution. The uEXPLORER PET/CT system is the first …

[PDF][PDF] Performance evaluation of a whole-body PET scanner using the NEMA protocol

G Brix, J Zaers, LE Adam, ME Bellemann… - Journal of Nuclear …, 1997 - Soc Nuclear Med
The scanner consists of four rings of 72 bismuth germanate block detectors each, covering
an axial field of view of 15.5 cm with a patient port of 56.2 cm. A single block detector is …

Characterization of the vereos digital photon counting PET system

M Miller, J Zhang, K Binzel, J Griesmer, T Laurence… - 2015 - Soc Nuclear Med
434 Objectives To characterize the first fully integrated digital detector PET/CT system.
Methods We previously reported basic performance of a prototype digital PET detector [1] …