Optimization of injected dose based on noise equivalent count rates for 2-and 3-dimensional whole-body PET

C Lartizien, C Comtat, PE Kinahan… - Journal of Nuclear …, 2002 - Soc Nuclear Med
The noise equivalent count (NEC) rate index is used to derive guidelines on the optimal
injected dose to the patient for 2-dimensional (2D) and 3-dimensional (3D) whole-body PET …

Comparative evaluation of two commercial PET scanners, ECAT EXACT HR+ and Biograph 2, using GATE

N Karakatsanis, N Sakellios, NX Tsantilas… - Nuclear Instruments and …, 2006 - Elsevier
Geant4 application for tomographic emission (GATE) is a generic Monte Carlo simulation
platform based on a general-purpose code GEANT4 and designed to simulate positron …

A high resolution animal PET scanner using compact PS-PMT detectors

M Watanabe, H Okada, K Shimizu… - … on Nuclear Science, 1997 - ieeexplore.ieee.org
A new high resolution PET scanner dedicated to animal studies has been designed, built
and tested. The system utilizes 240 block detectors, each of which consists of a new …

NEMA NU 2‐2012 performance studies for the SiPM‐based ToF‐PET component of the GE SIGNA PET/MR system

AM Grant, TW Deller, MM Khalighi… - Medical …, 2016 - Wiley Online Library
Purpose: The GE SIGNA PET/MR is a new whole body integrated time‐of‐flight (ToF)‐
PET/MR scanner from GE Healthcare. The system is capable of simultaneous PET and MR …

Performance evaluation of a PEM scanner using the NEMA NU 4—2008 small animal PET standards

W Luo, E Anashkin, CG Matthews - IEEE Transactions on …, 2010 - ieeexplore.ieee.org
The recently published NEMA NU 4-2008 Standards has been specially designed for
evaluating the performance of small animal PET scanners used in preclinical applications. In …

Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner

G Delso, S Fürst, B Jakoby, R Ladebeck… - Journal of nuclear …, 2011 - Soc Nuclear Med
The recently released Biograph mMR is the first commercially available integrated whole-
body PET/MR scanner. There are considerable advantages to integrating both modalities in …

Contribution of time of flight and point spread function modeling to the performance characteristics of the PET/CT Biograph mCT scanner

JM Martí-Climent, E Prieto, I Domínguez-Prado… - Revista Española de …, 2013 - Elsevier
OBJECTIVE: To characterize the performance of the Biograph mCT PET/CT TrueV scanner
with time of flight (TOF) and point spread function (PSF) modeling. MATERIAL AND …

Optimal whole-body PET scanner configurations for different volumes of LSO scintillator: a simulation study

JK Poon, ML Dahlbom, WW Moses… - Physics in medicine …, 2012 - iopscience.iop.org
The axial field of view (AFOV) of the current generation of clinical whole-body PET scanners
range from 15–22 cm, which limits sensitivity and renders applications such as whole-body …

[HTML][HTML] Quantitative comparison of PET performance—Siemens Biograph mCT and mMR

AM Karlberg, O Sæther, L Eikenes, PE Goa - EJNMMI physics, 2016 - Springer
Background Integrated clinical whole-body PET/MR systems were introduced in 2010. In
order to bring this technology into clinical usage, it is of great importance to compare the …

Micro insert: A prototype full-ring PET device for improving the image resolution of a small-animal PET scanner

H Wu, D Pal, TY Song, JA O'Sullivan… - Journal of nuclear …, 2008 - Soc Nuclear Med
A full-ring PET insert device should be able to enhance the image resolution of existing
small-animal PET scanners. Methods: The device consists of 18 high-resolution PET …