Mo1438 Relationship Between Stent Characteristics and Treatment Outcomes in Endoscopic Transmural Drainage of Pancreatic Pseudocysts
Background While stent characteristics are important determinants of treatment outcomes in
walled-off pancreatic necrosis (WOPN), their relationship to outcomes in pseudocysts is …
walled-off pancreatic necrosis (WOPN), their relationship to outcomes in pseudocysts is …
Relationship between stent characteristics and treatment outcomes in endoscopic transmural drainage of uncomplicated pancreatic pseudocysts
Background Transmural stents are placed at endoscopy to drain pancreatic fluid collections.
This study evaluated the relationship between stent placement and treatment outcomes in …
This study evaluated the relationship between stent placement and treatment outcomes in …
Prospective randomized trial comparing EUS and EGD for transmural drainage of pancreatic pseudocysts (with videos)
S Varadarajulu, JD Christein, A Tamhane… - Gastrointestinal …, 2008 - Elsevier
BACKGROUND: Although prior studies evaluated the role of EUS and EGD for drainage of
pancreatic pseudocysts, there are no randomized trials that compared the technical …
pancreatic pseudocysts, there are no randomized trials that compared the technical …
Endoscopic ultrasound-guided pancreatic pseudocyst drainage with lumen-apposing metal stents or plastic double-pigtail stents: A multifactorial analysis
N Ge, J Hu, S Sun, E Linghu, Z Jin, Z Li - Journal of translational …, 2017 - degruyter.com
Objective To compare the efficiency of plastic and metal stents for symptomatic pancreatic
pseudocyst (PP) drainage and analyze other main associated factors that affect the outcome …
pseudocyst (PP) drainage and analyze other main associated factors that affect the outcome …
734 Endoscopic transmural drainage of pancreatic pseudocysts: Multiple plastic stents versus metal stents-A systematic review and meta-analysis
Background Endoscopic ultrasound (EUS)-guided transmural drainage of pancreatic
pseudocysts by using multiple plastic or fully covered self-expandable metal stents …
pseudocysts by using multiple plastic or fully covered self-expandable metal stents …
Single-step EUS-guided transmural drainage of simple and complicated pancreatic pseudocysts
MR Antillon, RJ Shah, G Stiegmann, YK Chen - Gastrointestinal endoscopy, 2006 - Elsevier
BACKGROUND: Single-step EUS-guided transmural drainage of pseudocysts has been
reported, but there are no published prospective studies on clinical outcomes. OBJECTIVE …
reported, but there are no published prospective studies on clinical outcomes. OBJECTIVE …
Comparison of EUS-guided one-step transmural drainage of pancreatic pseudocysts and conventional transmural drainage: a prospective, non-blinded, single center …
Background/Aim. Endoscopic transmural drainage is a minimally invasive alternative to
surgery or percutaneous drainage of pancreatic pseudocyst. Limitation of this technique is …
surgery or percutaneous drainage of pancreatic pseudocyst. Limitation of this technique is …
Endoscopic drainage of pancreatic pseudocysts: long-term outcome and procedural factors associated with safe and successful treatment
D Cahen, E Rauws, P Fockens, G Weverling… - …, 2005 - thieme-connect.com
Results: A total of 92 patients were included (66 men, 26 women; median age 49 years). The
technical success rate of the drainage procedure was 97% and the mortality rate was 1 …
technical success rate of the drainage procedure was 97% and the mortality rate was 1 …
Metal versus plastic for pancreatic pseudocyst drainage: clinical outcomes and success
RZ Sharaiha, EM DeFilippis, P Kedia… - Gastrointestinal …, 2015 - Elsevier
Background Endoscopic transmural drainage of pancreatic pseudocysts (PPs) by using
double-pigtail (DP) plastic stents requires placement of multiple stents and can be restricted …
double-pigtail (DP) plastic stents requires placement of multiple stents and can be restricted …
Effectiveness and safety of a single 7-French plastic stent for endoscopic ultrasound-guided pancreatic pseudocyst drainage and long-term follow-up outcomes
N Pausawasdi, M Rugivarodom… - Journal of Medical …, 2021 - journals.lww.com
Background: Endoscopic ultrasound (EUS)-guided cystogastrostomy with a single 7-French
(Fr) double-pigtail stent (DPS) is less popular due to the concern of stent patency. We aimed …
(Fr) double-pigtail stent (DPS) is less popular due to the concern of stent patency. We aimed …
相关搜索
- transmural drainage pancreatic pseudocysts
- endoscopic drainage of pancreatic pseudocysts
- stent characteristics treatment outcomes
- treatment outcomes pancreatic pseudocysts
- metal stents pancreatic pseudocysts
- eus and egd pancreatic pseudocysts
- symptomatic pancreatic pseudocysts
- procedural factors pancreatic pseudocysts
- meta analysis pancreatic pseudocysts
- pseudocyst drainage plastic stent
- effectiveness and safety plastic stent
- pseudocyst drainage clinical outcomes
- pseudocyst drainage multifactorial analysis
- pseudocyst drainage effectiveness and safety
- stent characteristics pancreatic pseudocysts
- eus and egd transmural drainage