Non-invasive technique for monitoring intracranial pressure via the fontanelle in premature infants and newborns with hydrocephalus

K Von Wild, C Poerksen - Zeitschrift für Kinderchirurgie, 1980 - thieme-connect.com
In the course of one year 140 continuous non-invasive intracranial pressure measurements
have been performed in 83 patients via the fontanelle with a recording time of 30 minutes up …

Non-invasive intracranial pressure monitoring by fontanometry

MR Gaab, N Sörensen, A Brawanski… - Zeitschrift für …, 1980 - thieme-connect.com
Timely and reliable diagnosis of disturbances in CSF circulation or other disequilibrium of
intracranial pressure is necessary in early infancy in order to avoid further brain damage. In …

New fontanometer for continuous estimation of intracranial pressure in the newborn.

MJ Rochefort, P Rolfe, AR Wilkinson - Archives of disease in …, 1987 - adc.bmj.com
Intracranial pressure was estimated by a new pneumatic applanation fontanometer in
babies in intensive care. A close correlation with cerebrospinal fluid pressure was found on …

Intracranial Pressure Studies in Acutely Ill Neonates Using a Noninvasive Technique: A Three Year Experience

TNK Raju, D Vidyasagar - Intracranial Pressure IV, 1980 - Springer
In the newborn period, the presence of an open anterior fontanel (AF) permits one to assess
intracranial pressure (ICP) by palpation. For accurate recording of pressure however, this …

Monitoring of fontanelle pressure in neonates and infants. Evaluation of a new measuring technique, determination of normal values and clinical usefulness

JL Wayenberg, D Vermeylen… - Revue Medicale de …, 1993 - europepmc.org
The experience with 200 measurements of anterior fontanelle pressure with the Rotterdam
Teletransducer in newborns and infants is reported. Statistical analysis of 25 comparative …

Non-Invasive Intracranial Pressure Monitoring

DA De Jong, AIR Maas, E d Voort - Zeitschrift für …, 1984 - thieme-connect.com
Anterior fontanelle pressure was measured in 14 infants. A technique is described for
performing reproducible measurements utilising the Rotterdam Teletransducer. On …

Non‐invasive method for measuring intracranial pressure in normal newborn infants

RO Robinson, P Rolfe, P Sutton - Developmental Medicine & …, 1977 - Wiley Online Library
The aplanation principle has been proposed as a basis for a non‐invasive method of
measuring intracranial pressure in infants with patent anterior fontanelles. With minor …

The pressure depth curve in anterior fontanelle pressure monitoring

WCG Plandsoen, DA De Jong, AIR Maas… - Intracranial Pressure VI …, 1986 - Springer
In infants suspected of intracranial pathology it is often desirable to know the level of the
intracranial pressure (ICP). Whilst invasive procedures are seldom indicated, the open …

Non-invasive measurement of intracranial pressure in the newborn and the infant: the Rotterdam teletransducer.

JL Wayenberg, C Raftopoulos, D Vermeylen… - Archives of disease in …, 1993 - adc.bmj.com
Knowledge of intracranial pressure may be important in many clinical situations in neonates
and young infants. The best way to obtain this information would be a non-traumatic …

A new instrument for noninvasive measurement of intracranial pressure through the anterior fontanel: I. preliminary report

T Hayashi, S Kuramoto, E Honda, S Anegawa - Child's Nervous System, 1987 - Springer
A pressure sensor has been developed with which intracranial pressure of infants with open
anterior fontanell can be measured. The sensor consists of a light, small strain-gauge …