Electrocochleography observations in a series of cochlear implant electrode tip fold-overs

EMC Trecca, OF Adunka, JK Mattingly… - Otology & …, 2021 - journals.lww.com
Objective: Tip fold-over is a rare but serious complication of cochlear implant (CI) surgery.
The purpose of this study was to present intraoperative electrocochleography (ECochG) …

Evaluating cochlear insertion trauma and hearing preservation after cochlear implantation (CIPRES): a study protocol for a randomized single-blind controlled trial

S Jwair, RA Boerboom, H Versnel, RJ Stokroos… - Trials, 2021 - Springer
Background In order to preserve residual hearing in patients with sensorineural hearing loss
(SNHL) who receive a cochlear implant (CI), insertion trauma to the delicate structures of the …

Intraoperative correction of cochlear implant electrode translocation

WG Morrel, NF Manzoor, BM Dawant… - Audiology and …, 2022 - karger.com
Introduction: Translocation of precurved cochlear implant (CI) electrodes reduces hearing
outcomes, but it is not known whether it is possible to correct scalar translocation such that …

Detection of translocation of cochlear implant electrode arrays by intracochlear impedance measurements

Y Dong, JJ Briaire, M Siebrecht, HC Stronks… - Ear and …, 2021 - journals.lww.com
Objectives: Misplacement of the electrode array is associated with impaired speech
perception in patients with cochlear implants (CIs). Translocation of the electrode array is the …

Scalar localization of the electrode array after cochlear implantation: clinical experience using 64-slice multidetector computed tomography

JI Lane, RJ Witte, CLW Driscoll, JK Shallop… - Otology & …, 2007 - journals.lww.com
Objective: To use the improved resolution available with 64-slice multidetector computed
tomography (MDCT) in vivo to localize the cochlear implant electrode array within the basal …

Evaluation after cochlear implant surgery: Correlation of clinical outcome and imaging findings using flat-detector CT

A Stock, V Bozzato, SP Kloska, A Bozzato… - Clinical …, 2021 - Springer
Purpose Assessment of the cochlear implant (CI) electrode array position using flat-detector
computed tomography (FDCT) to test dependence of postoperative outcome on …

The case for intra-operative X-ray in cochlear implantation: Four illustrative cases and literature review

C Yu, S Debs, R Singh, S Kastetter… - Cochlear Implants …, 2022 - Taylor & Francis
Objectives: To demonstrate the utility of routine intraoperative plain film imaging in
optimizing outcomes in cochlear implantation. Introduction: Evolving surgical techniques …

Successful cochlear implantation of a split electrode array in a patient with far-advanced otosclerosis assisted by electromagnetic navigation: a case report

D Dejaco, D Prejban, N Fischer… - Otology & …, 2018 - journals.lww.com
Background: Incomplete electrode insertion is frequent when implanting ossified cochleae
with conventional linear electrodes. If split electrode arrays (SEA) are used, this complication …

Use of intraoperative CT scanning for quality control assessment of cochlear implant electrode array placement

RF Labadie, AD Schefano, JT Holder… - Acta oto …, 2020 - Taylor & Francis
Background: Imaging of cochlear implant (CI) electrode arrays (EAs) consists of
intraoperative fluoroscopy to rule out tip fold-over and/or post-operative computerized …

Cochlear implantation with a novel long straight electrode: the insertion results evaluated by imaging and histology in human temporal bones

S Sipari, M Iso-Mustajärvi, H Matikka… - Otology & …, 2018 - journals.lww.com
Background: The main focuses of modern cochlear implant surgery are to prevent damage
to the intracochlear structures and to preserve residual hearing. This is often achievable with …