DPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculations

J Sempau, SJ Wilderman… - Physics in Medicine & …, 2000 - iopscience.iop.org
Abstract A new Monte Carlo (MC) algorithm, thedose planning method'(DPM), and its
associated computer program for simulating the transport of electrons and photons in …

Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planning

IJ Chetty, B Curran, JE Cygler, JJ DeMarco… - Medical …, 2007 - Wiley Online Library
The Monte Carlo (MC) method has been shown through many research studies to calculate
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …

MMC-a high-performance Monte Carlo code for electron beam treatment planning

H Neuenschwander, TR Mackie… - Physics in Medicine & …, 1995 - iopscience.iop.org
Abstract The macro Monte Carlo (MMC) method has been developed to improve the speed
of traditional Monte Carlo (MC) high-energy electron transport calculations without loss in …

Development of a GPU-based Monte Carlo dose calculation code for coupled electron–photon transport

X Jia, X Gu, J Sempau, D Choi… - Physics in Medicine & …, 2010 - iopscience.iop.org
Monte Carlo simulation is the most accurate method for absorbed dose calculations in
radiotherapy. Its efficiency still requires improvement for routine clinical applications …

Monte Carlo treatment planning for photon and electron beams

N Reynaert, SC Van der Marck, DR Schaart… - Radiation Physics and …, 2007 - Elsevier
During the last few decades, accuracy in photon and electron radiotherapy has increased
substantially. This is partly due to enhanced linear accelerator technology, providing more …

3D electron dose calculation using a Voxel based Monte Carlo algorithm (VMC)

I Kawrakow, M Fippel, K Friedrich - Medical physics, 1996 - Wiley Online Library
A new model for calculating electron beam dose has been developed. The algorithm is
based on a two‐or three‐dimensional geometry defined by computerized tomography (CT) …

VMC++, electron and photon Monte Carlo calculations optimized for radiation treatment planning

I Kawrakow - Advanced Monte Carlo for Radiation Physics, Particle …, 2001 - Springer
VMC++ is a package for the class II condensed history Monte Carlo simulation of coupled
electron-photon transport optimized for three dimensional dose calculations used in the …

Determining the incident electron fluence for Monte Carlo‐based photon treatment planning using a standard measured data set

PJ Keall, JV Siebers, B Libby, R Mohan - Medical physics, 2003 - Wiley Online Library
An accurate dose calculation in phantom and patient geometries requires an accurate
description of the radiation source. Errors in the radiation source description are propagated …

Accurate characterization of Monte Carlo calculated electron beams for radiotherapy

CM Ma, BA Faddegon, DWO Rogers… - Medical …, 1997 - Wiley Online Library
Monte Carlo studies of dose distributions in patients treated with radiotherapy electron
beams would benefit from generalized models of clinical beams if such models introduce …

Beam modeling and beam model commissioning for Monte Carlo dose calculation‐based radiation therapy treatment planning: Report of AAPM Task Group 157

CMC Ma, IJ Chetty, J Deng, B Faddegon… - Medical …, 2020 - Wiley Online Library
Dose calculation plays an important role in the accuracy of radiotherapy treatment planning
and beam delivery. The Monte Carlo (MC) method is capable of achieving the highest …