Anti-tachycardia pacing for ventricular tachycardia: good even after being bad

MA Arias, A Puchol, E Castellanos… - Europace, 2007 - academic.oup.com
Implantable cardioverter-defibrillators (ICDs) include antitachycardia pacing (ATP) and high-
energy shocks (HES) for terminating ventricular tachyarrhythmias. ATP effectively terminates …

Safety and efficacy of programming a high number of antitachycardia pacing attempts for fast ventricular tachycardia: a prospective study

RP Martins, H Blangy, L Muresan, L Freysz… - Europace, 2012 - academic.oup.com
Aims Little is known about the optimal number of antitachycardia pacing (ATP) attempts to
programme in the fast ventricular tachycardia (FVT) zone. We sought to analyse the long …

Shock reduction with antitachycardia pacing before and during charging for fast ventricular tachycardias in patients with implantable defibrillators

PD Dallaglio, I Anguera, JBM Ferrer, L Pérez… - Revista Española de …, 2018 - Elsevier
Introduction and objectives Fast ventricular tachycardias in the ventricular fibrillation zone in
patients with an implantable cardioverter-defibrillator are susceptible to antitachycardia …

[HTML][HTML] Fast ventricular tachycardias in patients with implantable cardioverter-defibrillators: Efficacy and safety of antitachycardia pacing: A prospective and …

J Jiménez-Candil, A Arenal, A García-Alberola… - Journal of the American …, 2005 - jacc.org
To the Editor: Between 11% and 40% of detected monomorphic ventricular tachycardias
(VTs) in patients with implantable cardioverter-defibrillators (ICDs) have a cycle length (CL) …

Additional antitachycardia pacing programming strategies further reduce unnecessary implantable cardioverter-defibrillator shocks

B Joung, DR Lexcen, CK Ching, MT Silver, JP Piccini… - Heart Rhythm, 2020 - Elsevier
Background Antitachycardia pacing (ATP) is routinely used to terminate ventricular
tachyarrhythmias (VTs). However, little guidance exists on the most effective programming of …

Is inappropriate therapy a resolved issue with current implantable cardioverter defibrillators?

J Brugada - The American journal of cardiology, 1999 - Elsevier
Patients with an implantable cardioverter defibrillator (ICD) can undergo inappropriate
therapies if electrical activity not originating in the ventricle is wrongly recognized as …

Patient‐by‐patient basis anti‐tachycardia pacing for fast ventricular tachycardia with structural heart diseases

M Chinushi, H Furushima, O Saitoh… - Pacing and Clinical …, 2020 - Wiley Online Library
Background Anti‐tachycardia pacing (ATP) delivered from an implantable device is an
important tool to terminate ventricular tachycardia (VT). But its real‐world efficacy for fast VT …

[HTML][HTML] Impact of device programming on the success of the first anti-tachycardia pacing therapy: An anonymized large-scale study

S Shakibfar, O Krause, C Lund-Andersen, F Strycko… - Plos one, 2019 - journals.plos.org
Background Antitachycardia pacing (ATP) is an effective treatment for ventricular
tachycardia (VT). We evaluated the efficacy of different ATP programs based on a large …

[HTML][HTML] Optimal programming management of ventricular tachycardia storm in ICD patients

Z Qian, J Guo, Z Zhang, Y Wang, X Hou… - Journal of Biomedical …, 2015 - ncbi.nlm.nih.gov
Ventricular tachycardia storm (VTS) is defined as a life-threatening syndrome of three or
more separate episodes of ventricular tachycardia (VT) leading to implantable cardioverter …

915 ATP efficacy on terminating ventricular tachycardia by device type, indication, and ventricular median cycle length

M Brown, T Kurita, LD Sterns, EJ Schloss… - EP …, 2020 - academic.oup.com
Abstract Funding Acknowledgements Medtronic OnBehalf PainFree SST Background Anti-
tachycardia Pacing (ATP) is an established therapy that terminates VT without the need for …