Intraoperative cochlear implant reinsertion effects evaluated by electrode impedance
FM Toner, H Sanli, AC Hall, CS Birman - Otology & Neurotology, 2020 - journals.lww.com
Objectives: To assess the effect on impedance levels of intraoperative reinsertion of a
cochlear implant (CI) array compared with matched controls. Study Design: Retrospective …
cochlear implant (CI) array compared with matched controls. Study Design: Retrospective …
Cochlear implant electrode insertion
M Cosetti, JT Roland Jr - … Techniques in Otolaryngology-Head and Neck …, 2010 - Elsevier
Electrode insertion is the most important step in cochlear implant (CI) surgery. Optimal
electrode placement is a prerequisite for maximizing CI success. This article describes CI …
electrode placement is a prerequisite for maximizing CI success. This article describes CI …
Cochlear implant failures and revision
AAD Lassig, TA Zwolan, SA Telian - Otology & Neurotology, 2005 - journals.lww.com
Objective: To review cases involving implant failure and revision surgery in a large cochlear
implant program. Study Design: Retrospective case series. Setting: Cochlear implant …
implant program. Study Design: Retrospective case series. Setting: Cochlear implant …
Utility of intraoperative imaging in cochlear implantation: A systematic review
Background Many institutions routinely perform intraoperative imaging during cochlear
implant (CI) surgery to determine accurate electrode placement. Different modalities exist; …
implant (CI) surgery to determine accurate electrode placement. Different modalities exist; …
Improved cochlear implant electrode localization using coregistration of pre‐and postoperative CT
PJ Farnsworth, JC Benson, AM Nassiri… - Journal of …, 2023 - Wiley Online Library
Abstract Background and Purpose Artifact from cochlear implant electrodes degrades image
resolution on CT. Here, we describe the use of coregistered pre‐and postoperative CT …
resolution on CT. Here, we describe the use of coregistered pre‐and postoperative CT …
Multi-frequency electrocochleography and electrode scan to identify electrode insertion trauma during cochlear implantation
AA Saoji, MK Graham, WJ Adkins, K Koka, ML Carlson… - Brain Sciences, 2023 - mdpi.com
Intraoperative electrocochleography (ECOG) is performed using a single low-frequency
acoustic stimulus (eg, 500 Hz) to monitor cochlear microphonics (CM) during cochlear …
acoustic stimulus (eg, 500 Hz) to monitor cochlear microphonics (CM) during cochlear …
Orientation of the Cochlea From a Surgeon's Perspective
N Matsumoto, N Akagi-Tsuchihashi… - … & Neurotology Open, 2022 - journals.lww.com
Background: One of the mechanisms that cause tip fold-over is a misalignment between the
electrode array's coiling direction and the cochlea's curving direction. Objectives: We …
electrode array's coiling direction and the cochlea's curving direction. Objectives: We …
Analysis of intraoperative radiographic electrode placement during cochlear implantation
SH Gnagi, TR Baker, TR Pollei, DM Barrs - Otology & Neurotology, 2015 - journals.lww.com
Analysis of Intraoperative Radiographic Electrode Placement... : Otology & Neurotology
Analysis of Intraoperative Radiographic Electrode Placement During Cochlear Implantation …
Analysis of Intraoperative Radiographic Electrode Placement During Cochlear Implantation …
Evaluation after cochlear implant surgery: Correlation of clinical outcome and imaging findings using flat-detector CT
A Stock, V Bozzato, SP Kloska, A Bozzato… - Clinical …, 2021 - Springer
Purpose Assessment of the cochlear implant (CI) electrode array position using flat-detector
computed tomography (FDCT) to test dependence of postoperative outcome on …
computed tomography (FDCT) to test dependence of postoperative outcome on …
Verification of computed tomographic estimates of cochlear implant array position: a micro-CT and histologic analysis
J Teymouri, TE Hullar, TA Holden… - Otology & …, 2011 - journals.lww.com
Objective: To determine the efficacy of clinical computed tomographic (CT) imaging to verify
postoperative electrode array placement in cochlear implant (CI) patients. Study Design …
postoperative electrode array placement in cochlear implant (CI) patients. Study Design …