A Monte Carlo dose calculation tool for radiotherapy treatment planning

CM Ma, JS Li, T Pawlicki, SB Jiang… - Physics in Medicine …, 2002 - iopscience.iop.org
A Monte Carlo user code, MCDOSE, has been developed for radiotherapy treatment
planning (RTP) dose calculations. MCDOSE is designed as a dose calculation module …

Beam modeling and beam model commissioning for Monte Carlo dose calculation‐based radiation therapy treatment planning: Report of AAPM Task Group 157

CMC Ma, IJ Chetty, J Deng, B Faddegon… - Medical …, 2020 - Wiley Online Library
Dose calculation plays an important role in the accuracy of radiotherapy treatment planning
and beam delivery. The Monte Carlo (MC) method is capable of achieving the highest …

MCDOSE—A Monte Carlo dose calculation tool for radiation therapy treatment planning

CM Ma, JS Li, T Pawlicki, SB Jiang, J Deng - The Use of Computers in …, 2000 - Springer
Abstract MCDOSE is an EGS4 [1] user code developed at Stanford University for radiation
therapy treatment planning dose calculations. MCDOSE can be used to simulate the …

Validation of a Monte Carlo dose calculation tool for radiotherapy treatment planning

JS Li, T Pawlicki, J Deng, SB Jiang… - Physics in Medicine & …, 2000 - iopscience.iop.org
Abstract A new EGS4/PRESTA Monte Carlo user code, MCDOSE, has been developed as a
routine dose calculation tool for radiotherapy treatment planning. It is suitable for both …

Monte Carlo treatment planning for photon and electron beams

N Reynaert, SC Van der Marck, DR Schaart… - Radiation Physics and …, 2007 - Elsevier
During the last few decades, accuracy in photon and electron radiotherapy has increased
substantially. This is partly due to enhanced linear accelerator technology, providing more …

MMCTP: a radiotherapy research environment for Monte Carlo and patient-specific treatment planning

A Alexander, F DeBlois, G Stroian… - Physics in Medicine …, 2007 - iopscience.iop.org
Radiotherapy research lacks a flexible computational research environment for Monte Carlo
(MC) and patient-specific treatment planning. The purpose of this study was to develop a …

Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planning

IJ Chetty, B Curran, JE Cygler, JJ DeMarco… - Medical …, 2007 - Wiley Online Library
The Monte Carlo (MC) method has been shown through many research studies to calculate
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …

[HTML][HTML] Characterization of computer simulated radiotherapy beams for Monte-Carlo treatment planning

CM Ma - Radiation Physics and Chemistry, 1998 - Elsevier
Beam characterization consists of two parts: Beam simulation and beam modeling. The
EGS4/BEAM Monte-Carlo code system has been used for the simulation of the beams from …

Clinical implementation of a Monte Carlo treatment planning system

CM Ma, E Mok, A Kapur, T Pawlicki, D Findley… - Medical …, 1999 - Wiley Online Library
The purpose of this study was to implement the Monte Carlo method for clinical radiotherapy
dose calculations. We used the EGS4/BEAM code to obtain the phase‐space data for 6–20 …

An efficient framework for photon Monte Carlo treatment planning

MK Fix, P Manser, D Frei, W Volken… - Physics in Medicine & …, 2007 - iopscience.iop.org
Abstract Currently photon Monte Carlo treatment planning (MCTP) for a patient stored in the
patient database of a treatment planning system (TPS) can usually only be performed using …