Monte Carlo verification of IMRT dose distributions from a commercial treatment planning optimization system

CM Ma, T Pawlicki, SB Jiang, JS Li… - Physics in Medicine …, 2000 - iopscience.iop.org
The purpose of this work was to use Monte Carlo simulations to verify the accuracy of the
dose distributions from a commercial treatment planning optimization system (Corvus …

Effect of statistical uncertainties on Monte Carlo treatment planning

CM Ma, JS Li, SB Jiang, T Pawlicki… - Physics in Medicine …, 2005 - iopscience.iop.org
This paper reviews the effect of statistical uncertainties on radiotherapy treatment planning
using Monte Carlo simulations. We discuss issues related to the statistical analysis of Monte …

Monitor unit calculation for Monte Carlo treatment planning

CM Ma, RA Price, JS Li, L Chen, L Wang… - Physics in Medicine …, 2004 - iopscience.iop.org
In this work, we investigate a formalism for monitor unit (MU) calculation in Monte Carlo
based treatment planning. By relating MU to dose measured under reference calibration …

Dose calculation validation of VMC++ for photon beams

J Gardner, J Siebers, I Kawrakow - Medical Physics, 2007 - Wiley Online Library
The radiation therapy specific Voxel Monte Carlo (VMC++) dose calculation algorithm
achieves a dramatic improvement in MC dose calculation efficiency for radiation therapy …

Dosimetric evaluation of the clinical implementation of the first commercial IMRT Monte Carlo treatment planning system at 6 MV

E Heath, J Seuntjens, D Sheikh‐Bagheri - Medical physics, 2004 - Wiley Online Library
In this work we dosimetrically evaluated the clinical implementation of a commercial Monte
Carlo treatment planning software (PEREGRINE, North American Scientific, Cranberry …

A fluence-convolution method to calculate radiation therapy dose distributions that incorporate random set-up error

WA Beckham, PJ Keall, JV Siebers - Physics in Medicine & …, 2002 - iopscience.iop.org
Abstract The International Commission on Radiation Units and Measurements Report 62
(ICRU 1999) introduced the concept of expanding the clinical target volume (CTV) to form …

MMC-a high-performance Monte Carlo code for electron beam treatment planning

H Neuenschwander, TR Mackie… - Physics in Medicine & …, 1995 - iopscience.iop.org
Abstract The macro Monte Carlo (MMC) method has been developed to improve the speed
of traditional Monte Carlo (MC) high-energy electron transport calculations without loss in …

Simple beam models for Monte Carlo photon beam dose calculations in radiotherapy

MK Fix, H Keller, P Rüegsegger, EJ Born - Medical physics, 2000 - Wiley Online Library
Monte Carlo (code GEANT) produced 6 and 15 MV phase space (PS) data were used to
define several simple photon beam models. For creating the PS data the energy of starting …

Accurate characterization of Monte Carlo calculated electron beams for radiotherapy

CM Ma, BA Faddegon, DWO Rogers… - Medical …, 1997 - Wiley Online Library
Monte Carlo studies of dose distributions in patients treated with radiotherapy electron
beams would benefit from generalized models of clinical beams if such models introduce …

The commissioning and validation of Monaco treatment planning system on an Elekta Versa HD linear accelerator

JE Snyder, DE Hyer, RT Flynn… - Journal of applied …, 2019 - Wiley Online Library
Accurate beam modeling is essential to help ensure overall accuracy in the radiotherapy
process. This study describes our experience with beam model validation of a Monaco …