Differences among Monte Carlo codes in the calculations of voxel values for radionuclide targeted therapy and analysis of their impact on absorbed dose evaluations

M Pacilio, N Lanconelli, S Lo Meo, M Betti… - Medical …, 2009 - Wiley Online Library
Several updated Monte Carlo (MC) codes are available to perform calculations of voxel
values for radionuclide targeted therapy. The aim of this work is to analyze the differences in …

Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium: dose calculation …

P Carrasco, N Jornet, MA Duch, L Weber… - Medical …, 2004 - Wiley Online Library
An extensive set of benchmark measurement of PDDs and beam profiles was performed in a
heterogeneous layer phantom, including a lung equivalent heterogeneity, by means of …

[HTML][HTML] Dosimetric evaluation of Acuros XB Advanced Dose Calculation algorithm in heterogeneous media

A Fogliata, G Nicolini, A Clivio, E Vanetti, L Cozzi - Radiation oncology, 2011 - Springer
Background A study was realised to evaluate and determine relative figures of merit of a
new algorithm for photon dose calculation when applied to inhomogeneous media. Methods …

Verification by Monte Carlo methods of a power law tissue-air ratio algorithm for inhomogeneity corrections in photon beam dose calculations

S Webb, RA Fox - Physics in Medicine & Biology, 1980 - iopscience.iop.org
A Monte Carlo computer program has been used to calculate axial and off-axis depth dose
distributions arising from the interaction of an external beam of 60 Co radiation with a …

Conversion of CT numbers into tissue parameters for Monte Carlo dose calculations: a multi-centre study

B Vanderstraeten, PW Chin, M Fix, A Leal… - Physics in Medicine …, 2007 - iopscience.iop.org
The conversion of computed tomography (CT) numbers into material composition and mass
density data influences the accuracy of patient dose calculations in Monte Carlo treatment …

Removing the effect of statistical uncertainty on dose-volume histograms from Monte Carlo dose calculations

SB Jiang, T Pawlicki, CM Ma - Physics in Medicine & Biology, 2000 - iopscience.iop.org
Dose-volume histograms (DVHs) of the dose distributions calculated by the Monte Carlo
method contain statistical uncertainties. The Monte Carlo DVH can be considered as blurred …

[HTML][HTML] Monte Carlo simulations in radiotherapy dosimetry

P Andreo - Radiation Oncology, 2018 - Springer
Background The use of the Monte Carlo (MC) method in radiotherapy dosimetry has
increased almost exponentially in the last decades. Its widespread use in the field has …

The FLUKA Monte Carlo code coupled with the NIRS approach for clinical dose calculations in carbon ion therapy

G Magro, TJ Dahle, S Molinelli, M Ciocca… - Physics in Medicine …, 2017 - iopscience.iop.org
Particle therapy facilities often require Monte Carlo (MC) simulations to overcome intrinsic
limitations of analytical treatment planning systems (TPS) related to the description of the …

Monte Carlo dose mapping on deforming anatomy

H Zhong, JV Siebers - Physics in Medicine & Biology, 2009 - iopscience.iop.org
This paper proposes a Monte Carlo-based energy and mass congruent mapping (EMCM)
method to calculate the dose on deforming anatomy. Different from dose interpolation …

Dose calculation differences between Monte Carlo and pencil beam depend on the tumor locations and volumes for lung stereotactic body radiation therapy

T Zhuang, T Djemil, P Qi, A Magnelli… - Journal of applied …, 2013 - Wiley Online Library
Stereotactic body radiation therapy (SBRT) has been increasingly used as an efficacious
treatment modality for early‐stage non‐small cell lung cancer. The accuracy of dose …