Intra-cochlear electrode tip fold-over

D Sabban, M Parodi, M Blanchard… - Cochlear implants …, 2018 - Taylor & Francis
Cochlear implantation has been performed safely for over two decades but still has various
minor and major complications. We report two cases of an unusual complication of electrode …

Precurved cochlear implants and tip foldover: A cadaveric imaging study

DR Trakimas, ED Kozin, I Ghanad… - … –Head and Neck …, 2018 - journals.sagepub.com
Objective This study aims to define a reliable protocol for radiographic identification of
placement and tip foldover of newly designed precurved and straight electrodes. Study …

Misplaced Cochlear Implant Electrodes Outside the Cochlea: A Literature Review and Presentation of Radiological and Electrophysiological Findings

LL Cheung, J Kong, PY Chu, H Sanli… - Otology & …, 2022 - journals.lww.com
Background: Misplacement and malposition of a cochlear implant array can lead to poor
hearing outcomes. Where misplacements go undetected during the primary surgery …

Cochlear implant electrode array misplacement: a cautionary case report

E Muzzi, P Boscolo-Rizzo, R Santarelli… - The Journal of …, 2012 - cambridge.org
Objective: To report a series of pitfalls and complications in a case of cochlear implantation.
Method: Case report. Results: An 11-year-old boy affected by auditory neuropathy …

Cochlear implant electrode misplacement: a case series and contemporary review

TJ Shin, DJ Totten, BJ Tucker, RF Nelson - Otology & Neurotology, 2022 - journals.lww.com
Objective: To determine root causes leading to misplaced cochlear implant (CI) electrode
arrays and discuss their management using a case series and contemporary literature …

Potential insertion complications with cochlear implant electrodes

A Ishiyama, F Risi, P Boyd - Cochlear Implants International, 2020 - Taylor & Francis
Objectives: The aim of this discussion paper and literature review was to estimate the
incidence of a variety of complications associated with the surgical placement of cochlear …

Tip fold-over in cochlear implantation: case series

MG Zuniga, A Rivas, A Hedley-Williams… - Otology & …, 2017 - journals.lww.com
Objective: To describe the incidence, clinical presentation, and performance of cochlear
implant (CI) recipients with tip fold-over. Study Design: Retrospective case series. Setting …

Cochlear implant electrode misplacement: incidence, evaluation, and management

YLM Ying, JW Lin, JS Oghalai… - The …, 2013 - Wiley Online Library
Abstract Objectives/Hypothesis: To review the presentation and management of improper
electrode array placement, and to help guide clinical decision‐making. Study Design …

[HTML][HTML] Extra-cochlear insertion in cochlear implantation: a potentially disastrous condition

ED Gözen, F Tevetoğlu, HM Yener, E Kara… - The Journal of …, 2019 - ncbi.nlm.nih.gov
OBJECTIVES Cochlear implantation is an increasingly used technique for auditory
rehabilitation of pediatric and adult population. Safe implantation is achieved in most cases; …

Incomplete electrode extraction during cochlear implant revision

SY Kang, TA Zwolan, PR Kileny, JK Niparko… - Otology & …, 2009 - journals.lww.com
Objectives: To report 3 occurrences of incomplete electrode extraction during cochlear
implant revision, resulting in partial intracochlear retention of an implant electrode array …