Dosimetric evaluation of CR, 3DCRT and two types of IMRT for breast cancer after conservative surgery
F Zhang, Y Zhang, Y Wang - The Chinese-German Journal of Clinical …, 2013 - Springer
Objective The purpose of this study was to compare the dose distribution and dose volume
histogram (DVH) of the planning target volume (PTV) and organs at risk (OARs) among …
histogram (DVH) of the planning target volume (PTV) and organs at risk (OARs) among …
Dosimetric evaluation of conventional radiotherapy, 3‐D conformal radiotherapy and direct machine parameter optimisation intensity‐modulated radiotherapy for …
F Zhang, M Zheng - Journal of medical imaging and radiation …, 2011 - Wiley Online Library
Introduction: The use of conservative surgery combined with whole‐breast irradiation (WBI)
has been established as a valid alternative to mastectomy for the management of early …
has been established as a valid alternative to mastectomy for the management of early …
Evaluation of 3D-CRT, IMRT and VMAT radiotherapy plans for left breast cancer based on clinical dosimetric study
H Liu, X Chen, Z He, J Li - Computerized Medical Imaging and Graphics, 2016 - Elsevier
Objective This paper aims to compare dosimetric differences based on three types of
radiotherapy plans for postoperative left breast cancer. In particular, based on a clinical …
radiotherapy plans for postoperative left breast cancer. In particular, based on a clinical …
A comparison of doses for conventional and intensity modulated radiation therapy after breast-conserving operation in early-stage breast cancer
L Tian, Q Chi, X Lu, X Liu, T Wang, H Li - Chinese Journal of …, 2014 - inis.iaea.org
[en] Objective: To compare the dosimetry distribution between conventional radiotherapy
(CRT) and intensity modulated radiation therapy (IMRT) after breast-conserving surgery in …
(CRT) and intensity modulated radiation therapy (IMRT) after breast-conserving surgery in …
Verification and Evaluation of Radiation Doses received by organs at risk in (3D-CRT) and IMrt technique for breast cancer
NK Abdulkareem, FF Hassan… - Journal of Physics …, 2020 - iopscience.iop.org
External beam radiotherapy can be delivered more precisely by using three Dimensional
Conformal Radiotherapy (3D-CRT) technique, which is a traditional method used for whole …
Conformal Radiotherapy (3D-CRT) technique, which is a traditional method used for whole …
Dosimetrical optimization study of intensity modulated radiotherapy for intact breast
X Huang, G Jiang, J Chen, L Chen, WG HU… - China …, 2006 - pesquisa.bvsalud.org
purpose: Intensity-modulated radiotherapy (IMRT) can significantly improve the dosimetric
distribution of both the target and organs at risk compared to tangential irradiation for whole …
distribution of both the target and organs at risk compared to tangential irradiation for whole …
Dosimetric evaluation of different intensity-modulated radiotherapy techniques for breast cancer after conservative surgery
F Zhang, Y Wang, W Xu, H Jiang… - … in Cancer Research …, 2015 - journals.sagepub.com
Intensity-modulated radiotherapy (IMRT) potentially leads to a more favorite dose
distribution compared to 3-dimensional or conventional tangential radiotherapy (RT) for …
distribution compared to 3-dimensional or conventional tangential radiotherapy (RT) for …
Dosimetric absorption of intensity-modulated radiotherapy compared with conventional radiotherapy in breast-conserving surgery
Y Lin, B Wang - Oncology letters, 2015 - spandidos-publications.com
The aim of this study was to investigate the dosimetric benefits between intensity‑modulated
radiotherapy (IMRT) and conventional radiotherapy (CR) among patients receiving breast …
radiotherapy (IMRT) and conventional radiotherapy (CR) among patients receiving breast …
Determination and comparison of dosimetric parameters of three-dimensional conformal radiotherapy, field in field, and intensity-modulated radiotherapy techniques …
FS Takabi, MA Broomand, A Nickfarjam… - Journal of Cancer …, 2023 - journals.lww.com
Purpose: Three radiation therapy techniques for breast are common, namely three-
dimensional conformal radiotherapy (3D-CRT), Field-in-Field (FIF), and Intensıty-Modulated …
dimensional conformal radiotherapy (3D-CRT), Field-in-Field (FIF), and Intensıty-Modulated …
Dosimetric Investigation of FIF, VMAT, IMRT, H-VMAT, and H-IMRT Planning Techniques in Breast Cancer Radiotherapy
H SARAÇ CANBOLAT, N DEMİRCAN… - TURK ONKOLOJI …, 2023 - avesis.gazi.edu.tr
OBJECTIVE: It is aimed to compare the hybrid radiotherapy (RT) plans according to three-
dimensional field-in-field (FIF), intensity-modulated RT (IMRT), and volumetric-modulated …
dimensional field-in-field (FIF), intensity-modulated RT (IMRT), and volumetric-modulated …