Baseline impedance measured during high‐resolution esophageal impedance manometry reliably discriminates GERD patients
K Ravi, DM Geno, MF Vela, MD Crowell… - …, 2017 - Wiley Online Library
Background Baseline impedance measured with ambulatory impedance pH monitoring (MII‐
pH) and a mucosal impedance catheter detects gastroesophageal reflux disease (GERD) …
pH) and a mucosal impedance catheter detects gastroesophageal reflux disease (GERD) …
Esophageal contractile segment impedance from high-resolution impedance manometry correlates with mean nocturnal baseline impedance and acid exposure time …
A Horton, S Posner, B Sullivan, J Cornejo… - Diseases of the …, 2020 - academic.oup.com
Esophageal baseline impedance (BI) acquired during esophageal contraction (contractile
segment impedance [CSI]) is proposed to improve BI accuracy in gastroesophageal reflux …
segment impedance [CSI]) is proposed to improve BI accuracy in gastroesophageal reflux …
[HTML][HTML] Esophageal mucosal impedance assessment for the diagnosis of gastroesophageal reflux disease
RB Lages, LH de Souza Fontes… - Journal of …, 2024 - ncbi.nlm.nih.gov
Methods Sixty participants with typical symptoms of GERD underwent high-resolution
esophageal manometry, 24-hour multichannel intraluminal impedance-pH monitoring …
esophageal manometry, 24-hour multichannel intraluminal impedance-pH monitoring …
Mucosal impedance discriminates GERD from non-GERD conditions
F Ates, ES Yuksel, T Higginbotham, JC Slaughter… - Gastroenterology, 2015 - Elsevier
Background & Aims Current diagnostic tests for gastroesophageal reflux disease (GERD)
are suboptimal and do not accurately and reliably measure chronicity of reflux. A minimally …
are suboptimal and do not accurately and reliably measure chronicity of reflux. A minimally …
Twenty-four hour ambulatory simultaneous impedance and pH monitoring: a multicenter report of normal values from 60 healthy volunteers
S Shay, R Tutuian, D Sifrim, M Vela… - Official journal of the …, 2004 - journals.lww.com
OBJECTIVES Impedance monitoring is a new diagnostic method for gastroesophageal
reflux disease (GERD) where multiple impedance electrode pairs are placed on a standard …
reflux disease (GERD) where multiple impedance electrode pairs are placed on a standard …
Efficacy of esophageal impedance/pH monitoring in patients with refractory gastroesophageal reflux disease, on and off therapy
JM Pritchett, M Aslam, JC Slaughter, RM Ness… - Clinical …, 2009 - Elsevier
BACKGROUND & AIMS: Intraluminal impedance monitoring has given new dimensions to
the diagnosis of reflux disease. However, there is no defined algorithm for evaluating …
the diagnosis of reflux disease. However, there is no defined algorithm for evaluating …
[HTML][HTML] Reflux episodes and esophageal impedance levels in patients with typical and atypical symptoms of gastroesophageal reflux disease
BX Ye, LQ Jiang, L Lin, Y Wang, M Wang - Medicine, 2017 - journals.lww.com
To determine the relationship between baseline impedance levels and gastroesophageal
reflux, we retrospectively enrolled 110 patients (54 men and 56 female; mean age, 51±14 …
reflux, we retrospectively enrolled 110 patients (54 men and 56 female; mean age, 51±14 …
Proximal esophageal impedance baseline increases the yield of impedance‐pH monitoring for GERD diagnosis and is associated with heartburn response to PPI
M Ribolsi, M Frazzoni, L Marchetti… - …, 2023 - Wiley Online Library
Background Impairment of esophageal mucosal integrity as assessed by low mean
nocturnal baseline impedance (MNBI) measured in the distal esophagus increases the …
nocturnal baseline impedance (MNBI) measured in the distal esophagus increases the …
Reproducibility of multichannel intraluminal electrical impedance monitoring of gastroesophageal reflux
AJ Bredenoord, BLAM Weusten, R Timmer… - Official journal of the …, 2005 - journals.lww.com
OBJECTIVE Esophageal impedance measurement is a novel method for gastroesophageal
reflux monitoring. Reproducibility is an important aspect of every biomedical test. The aim of …
reflux monitoring. Reproducibility is an important aspect of every biomedical test. The aim of …
Esophageal acid exposure decreases intraluminal baseline impedance levels
BF Kessing, AJ Bredenoord… - Official journal of the …, 2011 - journals.lww.com
OBJECTIVES: Intraluminal baseline impedance levels are determined by the conductivity of
the esophageal wall and can be decreased in gastroesophageal reflux disease (GERD) …
the esophageal wall and can be decreased in gastroesophageal reflux disease (GERD) …