[HTML][HTML] Automatic adjustment of ventricular antitachycardia pacing and individualized device therapy

R Tripathi, C Gubran, C Jeavons - HeartRhythm Case Reports, 2022 - Elsevier
Automatic adjustment of ventricular antitachycardia pacing and individualized device therapy -
ScienceDirect Skip to main contentSkip to article Elsevier logo Journals & Books Search …

Initial clinical experience with a new automated antitachycardia pacing algorithm: feasibility and safety in an ambulatory patient cohort

R Yee, JD Fisher, U Birgersdotter-Green… - Circulation …, 2017 - Am Heart Assoc
Background: Antitachycardia pacing (ATP) in implantable cardioverter-defibrillators (ICD)
decreases patient shock burden but has recognized limitations. A new automated ATP …

Programmable external automatic antitachycardia pacing as a bridge to definitive therapy in patients with recurrent sustained ventricular tachycardia

TS Ahern, C Nydegger, AJ Greenspon… - Pacing and Clinical …, 1992 - Wiley Online Library
The efficacy and safety of external programmable automatic antitachycardia pacemakers
(ATPs) used in the critical care setting for recurrent sustained monomorphic ventricular …

Long-term efficacy of antitachycardia pacing for treatment of ventricular tachycardia in patients with implantable cardioverter/defibrillator

M Fiek, E Hoffmann, U Dorwarth, D Müller… - Zeitschrift fur …, 1999 - europepmc.org
Conclusions First, ATP is a highly effective therapy, independent of patients characteristics.
Second, short VT cycle length and long ATP coupling intervals were identified as predictors …

Efficacy of intrinsic antitachycardia pacing for ventricular tachycardia refractory to conventional burst pacing: A case series

T Kamakura, N Ueda, M Wada… - Journal of …, 2023 - Wiley Online Library
Intrinsic antitachycardia pacing (iATP) is a novel automated ventricular ATP algorithm that
designs ATP sequences based on the analysis of prior failed ATP. Real‐world data on the …

Antitachycardia pacing: which patients and which methods?

M Rosenqvist - The American journal of cardiology, 1996 - Elsevier
This article is a review on the value of antitachycardia pacing in patients with implantable
cardiac-defibrillators (ICD). Antitachycardia pacing is highly effective in terminating …

Failure of intrinsic antitachycardia pacing to terminate ventricular tachycardia and potential proarrhythmic effects

A Raina, M van Zyl, M Henrich, AJ Deshmukh… - Clinical …, 2023 - jacc.org
Intrinsic antitachycardia pacing (iATP) is a novel, automated antitachycardia pacing (ATP)
algorithm that provides individualized therapy to terminate ventricular tachycardia (VT). If the …

Randomized controlled comparison of antitachycardia pacing algorithms for termination of ventricular tachycardia

D Newman, P Dorian, J Hardy - Journal of the American College of …, 1993 - Elsevier
Objectives. This study compared the efficacy and safety of two antitachycardia pacing
algorithms in the treatment of ventricular tachycardia. Background. There is agreement that …

[HTML][HTML] Successful termination of ventricular tachycardia with intrinsic anti-tachycardia pacing

I Morishima, Y Kanzaki, Y Morita, Y Tsuji - Indian Pacing and …, 2021 - Elsevier
Intrinsic anti-tachycardia pacing (iATP) is a novel automated ATP algorithm that employs
post-pacing interval (PPI) to design the next ATP sequence based on an analysis of the prior …

Spontaneous ventricular tachycardia treated by antitachycardia pacing

N Nasir, A Pacifico, TK Doyle, NR Earle… - American Journal of …, 1997 - ajconline.org
Antitachycardia pacing for the termination of ventricular tachycardia (VT) is a standard
feature of implantable cardioverter-defibrillators (ICDs). New generation tiered-therapy …