Cross-sectional study of reversible airway obstruction in LAM: better evidence is needed for bronchodilator and inhaled steroid use

J Johnson, SR Johnson - Thorax, 2019 - thorax.bmj.com
… From 2015 onwards, reversibility was routinely tested in response to 2.5 mg nebulised
salbutamol. A positive response was defined as an increase in FEV 1 of at least 12% and 200 mL. …

Determining the optimal time to assess the reversibility of airway obstruction

J El Ghoul, M Abouda, M Triki, A Ghourabi, R Charfi - Lung India, 2019 - journals.lww.com
reversibility testing classifies the airway obstruction as reversible or irreversible and thereby
guides therapeutic … responded to the bronchodilator reversibility test in our sample and the …

[PDF][PDF] … effect of mode of inhaled salbutamol delivery on measures of small airways obstruction in asthma: a comparison of treatment delivered via spacer and nebuliser

A Singh, J Cowan, J Dummer - New Zealand Medical …, 2020 - nzmsj.scholasticahq.com
… Table 1: Mean measured values (3 sf) for pre- and post-salbutamol for all four lung function
tests for both MDI (and spacer) and nebuliser, along with their respective change scores and …

[HTML][HTML] Bronchodilation test with inhaled salbutamol versus bronchial methacholine challenge to make an asthma diagnosis: do they provide the same information?

R Louis, N Bougard, F Guissard, V Paulus… - The Journal of Allergy …, 2020 - Elsevier
… (5%) combined with salbutamol in the nebulizer cup. Sputum was then processed using the
… ), whereas those combining both positive reversibility test and positive bronchial challenge …

Nebulization versus metered-dose inhaler and spacer in bronchodilator responsiveness testing: a retrospective study

R Lu, Y Li, C Hu, P Pan, Q Zhao… - Therapeutic Advances in …, 2023 - journals.sagepub.com
… of delivery by a nebulizer in patients with chronic … testing are rare. This study assessed the
effects of salbutamol administered by an MDI with spacer versus a nebulizer on BDR testing of …

Effects of nebulizer fill volume on the efficacy and safety of the bronchodilator

H Saeed, H Rabea, NS Abdelwahab… - Journal of Drug Delivery …, 2020 - Elsevier
Reversibility of bronchoconstriction after inhalation of the drug can be used as an indicator
… One way analysis of variance (ANOVA) test was used to compare the results with the least …

Dose response to transnasal pulmonary administration of bronchodilator aerosols via nasal high-flow therapy in adults with stable chronic obstructive pulmonary …

J Li, M Zhao, M Hadeer, J Luo, JB Fink - Respiration, 2019 - karger.com
… a sidestream jet nebulizer with a mouthpiece. … nebulizer [25]. Albuterol (400 μg) delivered
via MDI with a valved holding chamber (VHC) is a standard method for bronchodilator testing

[HTML][HTML] Revefenacin, a once-daily, lung-selective, long-acting muscarinic antagonist for nebulized therapy: safety and tolerability results of a 52-week phase 3 trial in …

JF Donohue, E Kerwin, S Sethi, B Haumann… - Respiratory …, 2019 - Elsevier
reversibility test and received nebulizer or HandiHaler ® (Spiriva ® HandiHaler; Boehringer
Ingelheim, Ridgefield, CT, USA) training as appropriate. At the following clinic visit (day 1 of …

Response to bronchodilators administered via different nebulizers in patients with COPD exacerbation

B Cushen, A Alsaid, G Greene, RW Costello - Respiratory Care, 2023 - rc.rcjournal.com
nebulizer groups was performed using unpaired t test, Wilcoxon rank-sum test, or chi-square
test … 200 mL in accordance with ATS reversibility criteria. Volume response incorporated the …

Effects of flow rate on transnasal pulmonary aerosol delivery of bronchodilators via high-flow nasal cannula for patients with copd and asthma: protocol for a …

J Li, J Luo, Y Chen, L Xie, JB Fink - BMJ open, 2019 - bmjopen.bmj.com
… with reversible airflow … test lab for randomisation within 1–3 days of initial screening to
inhale saline and an escalating dose of albuterol administered by vibrating mesh nebuliser (VMN, …