An automatic rehabilitation assessment system for hand function based on leap motion and ensemble learning
… A novel multistandard compliant hand function assessment method using an infrared
imaging device. IEEE Journal of Biomedical and Health Informatics 23 (2):758–65. doi:10.1109/…
imaging device. IEEE Journal of Biomedical and Health Informatics 23 (2):758–65. doi:10.1109/…
[HTML][HTML] Validity and reliability of a depth camera–based quantitative measurement for joint motion of the hand
L Lv, J Yang, F Gu, J Fan, Q Zhu, X Liu - … of Hand Surgery Global Online, 2023 - Elsevier
… This study aimed to investigate the validity and reliability of a novel depth camera–based
contactless automatic measurement system to assess hand range … and an infrared camera. The …
contactless automatic measurement system to assess hand range … and an infrared camera. The …
A Novel Automated RGB-D Sensor-Based Measurement of Voluntary Items of the Fugl-Meyer Assessment for Upper Extremity: A Feasibility Study
… [19] proposed a novel hand assessment framework compliant with Swanson impairment
evaluation and FMA based on Leap Motion. Further, Lee et al. [20] combined Kinect v2 and …
evaluation and FMA based on Leap Motion. Further, Lee et al. [20] combined Kinect v2 and …
Automatic rehabilitation assessment method of upper limb motor function based on posture and distribution force
J Bai, G Li, X Lu, X Wen - Frontiers in Neuroscience, 2024 - frontiersin.org
… United Kingdom) is an optical motion capture system, that has become the gold standard for
… Infrared imaging devices are also used to assess hand function (Fang et al., 2019). Kinect …
… Infrared imaging devices are also used to assess hand function (Fang et al., 2019). Kinect …
Quantitative assessment of hand motor function for post-stroke rehabilitation based on HAGCN and multimodality fusion
… Conventionally, the assessment process relies … assess the hand motor function of patients
with post-stroke hemiplegia, this study proposes a novel multi-modality fusion assessment …
with post-stroke hemiplegia, this study proposes a novel multi-modality fusion assessment …
Technological evolution of image sensing designed by nanostructured materials
MA Iqbal, M Malik, TK Le, N Anwar, S Bakhsh… - ACS Materials …, 2023 - ACS Publications
… PD device using Si film is considered a novel approach for … Figure 14e shows the thermal
imaging system (including five … a micromachining-compatible approach that is suggested due …
imaging system (including five … a micromachining-compatible approach that is suggested due …
[HTML][HTML] Occupational therapy assessment for upper limb rehabilitation: A multisensor-based approach
SS Mahmoud, Z Cao, J Fu, X Gu, Q Fang - Frontiers in Digital Health, 2021 - frontiersin.org
… In this paper, we present a novel multisensor method for the assessment of upper limb … We
used a portable infrared imaging device to accurately measure multiple joint angles of a hand …
used a portable infrared imaging device to accurately measure multiple joint angles of a hand …
Active Range of Motion Measurement System Using an Optical Sensor to Evaluate Hand Functions
DSV Bandara, J Arata - … Conference of the IEEE Engineering in …, 2023 - ieeexplore.ieee.org
… Fu, “A novel multistandard compliant hand function assessment method using an infrared
imaging device,” IEEE Journal of Biomedical and Health Informatics, vol. 23, no. 2, pp. …
imaging device,” IEEE Journal of Biomedical and Health Informatics, vol. 23, no. 2, pp. …
Brunnstrom stage automatic evaluation for stroke patients by using multi-channel sEMG
F Wang, D Zhang, S Hu, B Zhu, F Han… - 2020 42nd annual …, 2020 - ieeexplore.ieee.org
… Kim, “Quantitative assessment test for upper-limb motor function by using EMG and … Novel
Multistandard Compliant Hand Function Assessment Method Using an Infrared Imaging Device…
Multistandard Compliant Hand Function Assessment Method Using an Infrared Imaging Device…
An automated system for motor function assessment in stroke patients using motion sensing technology: A pilot study
… system for upper-limb motor function assessment of stroke patients. The proposed system
… one Kinect V2) and one motor function assessment subsystem (to realize the automated …
… one Kinect V2) and one motor function assessment subsystem (to realize the automated …