[HTML][HTML] Fast open-source toolkit for water T2 mapping in the presence of fat from multi-echo spin-echo acquisitions for muscle MRI

F Santini, X Deligianni, M Paoletti, F Solazzo… - Frontiers in …, 2021 - frontiersin.org
… ; conversely, the T2 relaxation of the water component of the … time of 2 s/slice, plus 12 s per
dataset for the generation of the … Skeletal muscle quantitative nuclear magnetic resonance

KomaMRI. jl: An opensource framework for general MRI simulations with GPU acceleration

C Castillo‐Passi, R Coronado… - … Resonance in …, 2023 - Wiley Online Library
… equations in a two-step process, rotation and relaxation, for each time step Δ t = t n + 1 − t n
… in a computer with an 11th Gen Intel Core i7-1165G7 @ 2.80GHz × $$ \times $$ 8, with four …

[HTML][HTML] VirtMRI: A Tool for Teaching MRI

C Tönnes, C Licht, LR Schad, FG Zöllner - Journal of Medical Systems, 2023 - Springer
Magnetic resonance image formation is not trivial and remains … desktop browsers and is
open source. The user interface … We used these to generate the parameter maps by simply …

Autonomous magnetic resonance imaging

KS Ravi, S Geethanath - Magnetic Resonance Imaging, 2020 - Elsevier
… 3.6 [17] and related open-source libraries. The volunteer study was … Therefore, AMRI needed
to relax the time constraint in … 5 maps these characteristics of an IPS to the features of AMRI…

Opensource magnetic resonance imaging: Improving access, science, and education through global collaboration

L Winter, J Periquito, C Kolbitsch… - NMR in …, 2024 - Wiley Online Library
… such as T1 and T2 relaxation times, B1 and B0 field maps, and magnetic transfer ratios for a
… practices and areas that we believe require further improvement to enhance the generation

Osprey: Open-source processing, reconstruction & estimation of magnetic resonance spectroscopy data

G Oeltzschner, HJ Zöllner, SCN Hui… - Journal of neuroscience …, 2020 - Elsevier
… functions are added by generating Gauss-shaped signals with … , WM, and CSF tissue probability
maps. The Seg module then … These tCr ratios are reported as raw ratios, ie no relaxation

[HTML][HTML] Total mapping toolbox (TOMATO): an open source library for cardiac magnetic resonance parametric mapping

K Werys, I Dragonu, Q Zhang, I Popescu, E Hann… - SoftwareX, 2020 - Elsevier
… (T2) relaxation times are fundamental magnetic resonancemagnetic resonance (CMR)
imaging, T1 and T2-mapping … Concept of generating T1-maps. A series of images with …

Universal dynamic fitting of magnetic resonance spectroscopy

WT Clarke, C Ligneul, M Cottaar, IB Ip… - Magnetic Resonance …, 2024 - Wiley Online Library
… The toolbox is shared as a fully open-source software with … -echo techniques that measure
relaxation parameters, 18 which … application of event related activation could be used to map

Automated analysis of immediate reliability of T2 and T2* relaxation times of hip joint cartilage from 3 T MR examinations

JM Bugeja, SS Chandra, A Neubert, J Fripp… - Magnetic Resonance …, 2021 - Elsevier
… Regional studies assessing T2 and T2* relaxation times in hip joint cartilage have identified
that both T2 and T2* mapping relaxation times vary across different regions and depths of …

[HTML][HTML] Fast calculation software for modified Look-Locker inversion recovery (MOLLI) T1 mapping

YC Kim, KR Kim, H Lee, YH Choe - BMC Medical Imaging, 2021 - Springer
… of computation time in cardiac magnetic resonance imaging. … the quantification of T1
longitudinal relaxation time on a pixel-… The implementation details available as open source may …