Establishing a reference dose–response calibration curve for dicentric chromosome aberrations to assess accidental radiation exposure in Saudi Arabia

GA Alsbeih, KS Al-Hadyan, NM Al-Harbi… - Frontiers in Public …, 2020 - frontiersin.org
… issues when reacting to a radiation emergency (2). An … detect partial body exposure,
and its sensitivity to doses down to … technique for absorbed radiation dose assessment, it is …

Reassessment of internal thyroid doses to 1,080 children examined in a screening survey after the 2011 Fukushima nuclear disaster

E Kim, K Yajima, S Hashimoto, K Tani, Y Igarashi… - Health …, 2020 - journals.lww.com
… However, it has been difficult to assess internal thyroid doses … and on another part of the
body for each subject (for example, … , in each of which a small sealed source was installed. The …

Patient-specific organ dose calculated by dose tracking software based on monte carlo simulation in pediatric abdominal CT

Y Innan - 2020 - digital.car.chula.ac.th
… of the mean absorbed dose to the various body organs and … the radiation detriment for a
given organ from a whole-body … this analysis provides several measures of radiation dose from …

Radiation Protection of Staff and the Public

M Rosenbloom, WPM Mayles - Handbook of Radiotherapy …, 2021 - taylorfrancis.com
… In assessing the neutron dose rate related to the photon dose rate in the primary beam, a …
parts of the body. These precautions are also appropriate for handling sealed sources. …

Study logistics that can impact medical countermeasure efficacy testing in mouse models of radiation injury

AL DiCarlo, Z Perez Horta, CI Rios… - … journal of radiation …, 2021 - Taylor & Francis
… to assess efficacy of a medical countermeasure for radiation-… and body weight changes) has
been linked to radiation dose … sources originate from a sealed radionuclide source, 137 Cs …

Quality control in blood irradiation

F Lopes, RCG Rocha, E Munhoz, FC Trigo… - … Journal of Radiation …, 2023 - bjrs.org.br
… co-transfused lymphocytes, their body will produce an immune … radiation contamination
and check the integrity of the sealed … The distribution analysis is performed only in a half plane …

AAPM medical physics practice guideline 14. a: Yttrium‐90 microsphere radioembolization

NC Busse, MSAL Al‐Ghazi… - Journal of applied …, 2024 - Wiley Online Library
assessment of the prior absorbed dose delivered to the liver. … the IR suite in case of an
emergency or radioactive spill. The … The absorbed dose to the lungs and other non-target organs

Exposure due to Radionuclides in Food Other than During a Nuclear or Radiological Emergency. Part 1: Technical Material

World Health Organization - 2023 - inis.iaea.org
… Information on dietary consumption is also an essential tool in assessing the radiation dose
… authorization by the regulatory body. On the other hand, emergency exposure situations and …

Safety Culture in Handling Radioactive Materials for Radiation Practitioners: A Review

SA Othman - International Journal of Public Health Research, 2021 - spaj.ukm.my
… concrete slabs, which may be sealed by, for example, asphalt. … , will reduce the absorbed
dose towards the body. Next, … of radiation units, image quality and patient dose assessment.…

Radiological and Nuclear Terrorism

PA Karam - Springer
radiation safety professionals, emergency response planners, … an absorbed dose of 1 Gy
and an equivalent dose of 20 Sv. … -body counting, or other technique—or a rough assessment