Monte Carlo calculation of whole body counter efficiency factors for different computational phantoms

CVG Ferreira, JS Piedade, MRD Prado… - Applied Radiation and …, 2023 - Elsevier
… To configure the VMC code to simulate the WBC system using different voxel phantoms, a …
the BOMAB phantom as a calibration device for in-vivo whole-body measurement systems, it …

Monte Carlo simulations of a standing geometry whole body counter: Effects of skeletal sampling, age, sex and phantom size on calibration

CS Charubala, V Santhanakrishnan… - Radiation Physics and …, 2024 - Elsevier
Voxel files for FLUKA Monte Carlo code are created from the data provided by ICRP … reference
phantoms by ICRP, numerical calibration of in-vivo monitoring systems using Monte Carlo

[HTML][HTML] Virtual calibration of whole-body counters to consider the size dependency of counting efficiency using Monte Carlo simulations

MS Park, HS Kim, J Yoo, CH Kim, WI Jang… - Nuclear Engineering and …, 2021 - Elsevier
Monte Carlo methods have been used previously to calibrate in vivo measurement systems.
simulations with the computational phantoms of different sizes developed by different …

Quantifying tissue optical properties of human heads in vivo using continuous-wave near-infrared spectroscopy and subject-specific three-dimensional Monte Carlo …

TC Kao, KB Sung - Journal of Biomedical Optics, 2022 - spiedigitallibrary.org
method, we simulated reflectance spectra of the phantoms with CUDAMCML 38 and performed
calibrating … The edge length of one voxel in our voxel-based model is 0.93 mm, which is …

The effect of calibration factors and recovery coefficients on 177Lu SPECT activity quantification accuracy: a Monte Carlo study

K Ramonaheng, JA van Staden, H du Raan - EJNMMI physics, 2021 - Springer
… It is recommended that phantom or Monte Carlo (MC) simulation studies be used to …
Another important consideration of PVE is image sampling. Due to the limited voxel size, a …

Monte Carlo dose simulation for in-vivo X-ray nanoscopy

F Wagner, M Thies, M Karolczak, S Pechmann… - Bildverarbeitung für die …, 2022 - Springer
phantom of a mouse leg during an in-vivo acquisition. That … this work to calibrate the simulated
dose values to the XRM system. … We derive densities directly from voxel intensities using a …

A phantom-based experimental and Monte Carlo study of the suitability of in-vivo diodes and TLD for entrance in-vivo dosimetry in small-to-medium sized 6 MV photon …

A Ketabi, S Karbasi, R Faghihi… - Radiation Physics and …, 2022 - Elsevier
… , the calculations were repeated with lateral voxel dimensions ranging from 1 mm to 10 mm.
… as those associated with the calibration procedure, dosimeter manufacturing variations, etc. …

Monte Carlo modeling and simulation of a new 3D printed phantom for whole-body counter calibration

EMR Andrade, TCF Fonseca, L Paixao, BM Mendes - 2023 - inis.iaea.org
… computational voxel phantom, exploring the system'ssimulations regarding the counting
efficiency of the NaI(Tl) scintillator detector within the context of the in vivo monitoring system

Monte Carlo simulations of the whole-body counter at Spiez Laboratory Switzerland: Impact of phantom size and biokinetic model

L Desorgher, N Mosimann, R Althaus, C Wirz… - … Measurements, 2022 - Elsevier
… the need of using phantoms with different sizes to calibrate a … To validate the use of ICRP
voxel phantoms in our code (see … to study the impact of biokinetics with ICRP models on in-vivo

Measurement‐based validation of a commercial Monte Carlo dose calculation algorithm for electron beams

G Pittomvils, E Bogaert, E Traneus… - Medical …, 2022 - Wiley Online Library
… , clinical routine settings of 2 × 2 × 2-mm 3 dose voxels and a … relying on EBT film dosimetry
in heterogeneous phantoms. … is complementary to the in vivo verification of individual …