[HTML][HTML] Fluid-structure interaction in coronary stents: a discrete multiphysics approach
… or polymer stent is deployed to open the stenosed artery or … study the mechanical deformation
of the coronary stent and its … distribution within the local hemodynamic environment as well …
of the coronary stent and its … distribution within the local hemodynamic environment as well …
… study of effects of material properties, strain level, and friction coefficient on smart stent behavior and peripheral artery performance during the interaction process
F Nematzadeh - Journal of Intelligent Material Systems and …, 2022 - journals.sagepub.com
… internal curvature of the stents, displays the SIM change and is … mechanical enactment for
the Peripheral Artery Smart stent … formation between arteries, stenosis degree of arteries, the …
the Peripheral Artery Smart stent … formation between arteries, stenosis degree of arteries, the …
The Technological Advancement to Engineer Next‐Generation Stent‐Grafts: Design, Material, and Fabrication Techniques
E Vahabli, J Mann, BS Heidari… - Advanced …, 2022 - Wiley Online Library
… design of metal stents can influence the mechanical performance of … exhibited significantly
lower diameter stenosis at 180 d and … cell–material interactions to promote biocompatibility. …
lower diameter stenosis at 180 d and … cell–material interactions to promote biocompatibility. …
How does stent expansion alter drug transport properties of the arterial wall?
… in the arterial wall. We establish relationships between mechanical force generated through
device expansion and … The stent expansion will also cause local changes to porosity in the …
device expansion and … The stent expansion will also cause local changes to porosity in the …
Biomechanical interpretation of observed fatigue fractures of peripheral Nitinol stents in the superficial femoral arteries through in silico modelling
… on the device due to the interaction with the stenotic vessel, using a … a plaque disruption and
a loss in mechanical properties. … The simulation environment is constantly set at 37 to mimic …
a loss in mechanical properties. … The simulation environment is constantly set at 37 to mimic …
Biomechanical mechanism of distal stent-graft-induced new entry deterioration after thoracic endovascular aortic repair
… of the left brachial artery to calculate individual Windkessel model … fluid–structure interaction
among the blood flow, stent-graft, … aims to reveal the biomechanical mechanics of the dSINE …
among the blood flow, stent-graft, … aims to reveal the biomechanical mechanics of the dSINE …
[HTML][HTML] Computational modeling of braided venous stents—Effect of design features and device-tissue interaction on stent performance
R Ubachs, O van der Sluis, S Smith… - journal of the mechanical …, 2023 - Elsevier
… increasing the lumen of a stenotic vessel by applying a chronic (… little resistance, while
high stent to environment friction levels … Carotid artery stenting simulation: From patient-specific …
high stent to environment friction levels … Carotid artery stenting simulation: From patient-specific …
Effects of different positions of intravascular stent implantation in stenosed vessels on in-stent restenosis: an experimental and numerical simulation study
S He, W Liu, K Qu, T Yin, J Qiu, Y Li, K Yuan… - Journal of …, 2020 - Elsevier
… changes in intravascular mechanical environment … , through balloon injury and high-fat
diet culture, we obtained animal model with stenotic carotid artery and conducted different stent …
diet culture, we obtained animal model with stenotic carotid artery and conducted different stent …
Evaluation of the role of peripheral artery plaque geometry and composition on stent performance
C Noble, KD Carlson, E Neumann, S Doherty… - … of the mechanical …, 2021 - Elsevier
… to vessel stenosis that obstructs blood flow in the arteries of the … the mechanical environment
to be simulated and stent designs … of the stent-artery interaction based on artery geometries …
to be simulated and stent designs … of the stent-artery interaction based on artery geometries …
[HTML][HTML] Patient-specific modelling of stent overlap: Lumen gain, tissue damage and in-stent restenosis
… that stent overlap created a hemodynamic environment that … Therefore, interactions
between stent, balloon and artery … low initial stenosis and a sudden change of arterial curvature…
between stent, balloon and artery … low initial stenosis and a sudden change of arterial curvature…