Occlusion Devices for Cardiovascular Disease

Y Zeng, Y Zhang, C Tu - Application of Biomaterials in the Treatment of …, 2024 - Springer
… in five major applications, the atrial septal defect, the patent … Recently, the initial clinical
results also suggested that GCO … ends of the MP35N “double-umbrella” framework. The device …

[PDF][PDF] Percutaneous closure of restrictive-type perimembranous ventricular septal defect using the new KONAR multifunctional occluder: Midterm outcomes of the first …

LS Daou, ZS Saliba - academia.edu
… Since the first Rashkind double umbrella device,6 occluders … procedure as well as to use
their clinical records after they were … atrial septal defect (n = 1), and a bicuspid AoV (n = 1). The …

[HTML][HTML] First-in-human experience with a novel fully bioabsorbable occluder for ventricular septal defect

L Chen, S Hu, Z Luo, G Butera, Q Cao, F Zhang… - Cardiovascular …, 2020 - jacc.org
Use of partially bioabsorbable occluders for atrial septal defect closure appears to circumvent
… After occluder deployment, a “double-umbrella” framework shape is achieved by pulling …

Itzhak Kronzon, Juan Manuel Monteagudo, Francesco F. Faletra, Priti Mehla, and

M Saric - The ESC Textbook of Cardiovascular Imaging, 2021 - books.google.com
… for the transcatheter closure of atrial defects and of patent … was reported; the VSD was
closed using a double-umbrella … septal defect occluder: initial clinical applications in children. …

Occlusion Devices for Cardiovascular

Y Zeng, Y Zhang, C Tu - Application of Biomaterials in the Treatment of … - Springer
… ) Secundum atrial septal defect Secundum atrial septal defect … Recently, the initial clinical
results also suggested that GCO … ends of the MP35N “double-umbrella” framework. The device …

Transcatheter closure of periprosthetic leaks

M Gössl - Progress in Cardiovascular Diseases, 2022 - Elsevier
… were coil occlusions 10 , 11 and the double umbrella device. … images the left atrial orifice
of the defect may appear large … We have found the use of the135-cm SafeSept transseptal …

Septal Defects

SK Tsai, JK Wang, SJ Chen - … in Pediatric Congenital Cardiac Surgery and …, 2024 - Springer
… a spring-loaded dacron double-umbrella design and a framework with … overstretch during
device closure of atrial septal defect (ASD) in a … Off‐label use of duct occluder devices to close

[HTML][HTML] Comparative effectiveness of devices for transcatheter closure of atrial septal defects: Systematic review and network meta-analysis

V Vishwanath, S Akseer, C Frankfurter, S Reza… - Archives of …, 2022 - Elsevier
… in the atrial septum; the current preferred treatment is transcatheter device closure. The aim
… the comparative effectiveness and safety of atrial septal defect closure devices. The methods …

[HTML][HTML] CD34 antibody-coated biodegradable fiber membrane effectively corrects atrial septal defect (ASD) by promoting Endothelialization

B Chu, X Li, S Fan, J He, X Ge, H Li, C Chen, Z Wang… - Polymers, 2022 - mdpi.com
… , double-umbrella structures placed at the heart defect site [3]. … , the aim is to achieve complete
closure of the heart defect. … body and was approved for clinical use in 1997 by the Food …

[图书][B] Atrial Septal Defects: Diagnosis and Management

AA Pillai, V Balasubramanian - 2021 - books.google.com
use by medical, scientific or health-care professionals and is provided strictly as a supplement
to the medical … children with atrial septal defect considered too small for surgical closure. …