State of the art in total body PET

S Vandenberghe, P Moskal, JS Karp - EJNMMI physics, 2020 - Springer
… the direction of gamma photons emitted from the source and the … by a set of closely placed
point sources, and sensitivity can … length for a point source, short object 10 cm, a 100-cm-long …

Performance assessment of the 2 γpositronium imaging with the total-body PET scanners

P Moskal, D Kisielewska, R Y. Shopa, Z Bura… - EJNMMI physics, 2020 - Springer
… of the scanner was varied between 10 cm and 200 cm. … , 5×10 6 events with the emission
of prompt gamma from 44 Sc … are expected for LYSO-based total-body PET. These numbers …

Simulating NEMA characteristics of the modular total-body J-PET scanner—an economic total-body PET from plastic scintillators

P Moskal, P Kowalski, RY Shopa… - Physics in Medicine …, 2021 - iopscience.iop.org
… , for 140 cm long tomograph and the point source placed in … locations (x = 1 cm, 10 cm and
20 cm) and two axial—at the … source of back-to-back gamma photons with length of 70 cm was …

External Cesium-137 doses to humans from soil influenced by the Fukushima and Chernobyl nuclear power plants accidents: a comparative study

KM Wai, D Krstic, D Nikezic, TH Lin, PKN Yu - Scientific reports, 2020 - nature.com
… external effective doses due to the 137 Cs derived gamma photons … The effective dose was
calculated based on multiple … Concentrations in the top soil (0–10 cm) were presented. The …

Toward an effective use of laser-driven very high energy electrons for radiotherapy: Feasibility assessment of multi-field and intensity modulation irradiation schemes

L Labate, D Palla, D Panetta, F Avella, F Baffigi… - Scientific reports, 2020 - nature.com
… depths in the range from 5 to 10 cm with mm resolution. The … passive collimator, placed at
about 38 cm downstream of the … ) so as to reduce the X/\(\gamma\)-ray photons produced via …

EANM dosimetry committee recommendations for dosimetry of 177Lu-labelled somatostatin-receptor-and PSMA-targeting ligands

K Sjögreen Gleisner, N Chouin, PM Gabina… - European journal of …, 2022 - Springer
… of gamma photons … located in other source regions). When the range of particle emissions
is much shorter than the organ dimensions, the AF for self-absorbed dose is very near or equal

An extensive study on the neutron-gamma shielding and mass stopping power of (70-x) CRT–30K2O–xBaO glass system for 252Cf neutron source

M Sarihan, R Boodaghi Malidarre… - Environmental …, 2023 - Taylor & Francis
… The 2 cm thick cubic sample is cited 10 cm away from the … was found to decrease moderately
with increasing gamma … Furthermore, the LAC variations of the glass samples are close

Estimating dose delivery accuracy in stereotactic body radiation therapy: a review of in-vivo measurement methods

M Esposito, E Villaggi, S Bresciani, S Cilla… - Radiotherapy and …, 2020 - Elsevier
source of discrepancy, as the PD was placed in a high dose … were excellent with a gamma
passing rate equal to 96%. … by periodic QA before treatment effectiveness was compromised. …

Integrating an open source Monte Carlo code “MCsquare” for clinical use in intensity‐modulated proton therapy

W Deng, JE Younkin, K Souris, S Huang… - Medical …, 2020 - Wiley Online Library
… -based dose calculation code with MPI capability, web-based second … with PSQA
measurements using gamma index analysis with … , we observed a discrepancy near the Bragg …

EANM Dosimetry Committee series on standard operational procedures for internal dosimetry for 131I mIBG treatment of neuroendocrine tumours

J Gear, C Chiesa, M Lassmann, PM Gabiña, J Tran-Gia… - EJNMMI physics, 2020 - Springer
… volumes ranging in diameter up to 10 cm or more. Larger volumes … based on bio-kinetics,
particularly the whole-body absorbed … As gamma cameras are not optimised for high-activity …