ICRP publication 145: adult mesh-type reference computational phantoms
… to industrial radiography sources near the body, reflecting different body sizes or postures, …
) were simulated as point sources placed near each of the MCRPs. Ir emits gamma rays with …
) were simulated as point sources placed near each of the MCRPs. Ir emits gamma rays with …
Report of AAPM Task Group 155: megavoltage photon beam dosimetry in small fields and non‐equilibrium conditions
IJ Das, P Francescon, JM Moran, A Ahnesjö… - Medical …, 2021 - Wiley Online Library
… For example, f msr in Gamma Knife, CyberKnife and … and 10 cm for a field size of 10 cm
× 10 cm defined at a source to … Emphasis is placed on treatment planning dose calculation …
× 10 cm defined at a source to … Emphasis is placed on treatment planning dose calculation …
Shielding characteristics of nanocomposites for protection against X-and gamma rays in medical applications: effect of particle size, photon energy and nano-particle …
E Mansouri, A Mesbahi, R Malekzadeh… - Radiation and …, 2020 - Springer
… There is a wide body of information in the literature regarding … The gamma radiation sources
in this study were 137 Cs (0.662 … They also found that increasing the energy of the gamma …
in this study were 137 Cs (0.662 … They also found that increasing the energy of the gamma …
[HTML][HTML] Kidney dosimetry in 777 patients during 177Lu-DOTATATE therapy: aspects on extrapolations and measurement time points
M Sandström, N Freedman, K Fröss-Baron, T Kahn… - EJNMMI physics, 2020 - Springer
… In parallel to dose planning before external beam … dose is based on the activity distribution
and kinetics over time for the relevant organs and tissues, generally obtained by gamma …
and kinetics over time for the relevant organs and tissues, generally obtained by gamma …
Neutron dose and its measurement in proton therapy—current state of knowledge
RA Hälg, U Schneider - The British journal of radiology, 2020 - academic.oup.com
… of neutron ambient dose equivalent in a specific location, the … measurements of neutron
and gamma-ray doses in a water … Bragg peak with a modulation of 10 cm from a pencil beam …
and gamma-ray doses in a water … Bragg peak with a modulation of 10 cm from a pencil beam …
EpiXS: A Windows-based program for photon attenuation, dosimetry and shielding based on EPICS2017 (ENDF/B-VIII) and EPDL97 (ENDF/B-VI. 8)
FC Hila, A Asuncion-Astronomo, CAM Dingle… - Radiation Physics and …, 2021 - Elsevier
… plots with the most prominent appearing near the curve of the K-… The energy of this gamma
ray (88.0336 keV) is found in-between … The effective atomic numbers for borosilicate glass …
ray (88.0336 keV) is found in-between … The effective atomic numbers for borosilicate glass …
Gamma radiation shielding properties of some Bi-Sn-Zn alloys
N Rani, YK Vermani, T Singh - Journal of Radiological Protection, 2020 - iopscience.iop.org
… atomic number, measured experimentally, were found to be in close … the most sensitive organ
of the human body, the brain [6]. … The detector and source were kept at a distance of 10 cm …
of the human body, the brain [6]. … The detector and source were kept at a distance of 10 cm …
Small-field radiotherapy photon beam output evaluation: detectors reviewed
… stereotactic field diode (SFD) are close to unity for the smallest field … , all of which are based
on a 10 × 10 cm 2 reference field. The … EBT3 in terms of gamma evaluation passing rates and …
on a 10 × 10 cm 2 reference field. The … EBT3 in terms of gamma evaluation passing rates and …
[HTML][HTML] EANM Dosimetry Committee series on standard operational procedures for internal dosimetry for 131I mIBG treatment of neuroendocrine tumours
J Gear, C Chiesa, M Lassmann, PM Gabiña, J Tran-Gia… - EJNMMI physics, 2020 - Springer
… volumes ranging in diameter up to 10 cm or more. Larger volumes … based on bio-kinetics,
particularly the whole-body absorbed … As gamma cameras are not optimised for high-activity …
particularly the whole-body absorbed … As gamma cameras are not optimised for high-activity …
Investigation and mapping of natural and artificial radioactivity in sediment samples from Borçka Black Lake, Artvin-Turkey
… can cause certain damage to the body after a while, and … that the distribution of absorbed
gamma dose rate (AGDR) level … in this study are close to the concentrations found in Brullus, …
gamma dose rate (AGDR) level … in this study are close to the concentrations found in Brullus, …