ICRP publication 145: adult mesh-type reference computational phantoms

CH Kim, YS Yeom, N Petoussi-Henß… - Annals of the …, 2020 - journals.sagepub.com
… to industrial radiography sources near the body, reflecting different body sizes or postures, …
) were simulated as point sources placed near each of the MCRPs. Ir emits gamma rays with …

Report of AAPM Task Group 155: megavoltage photon beam dosimetry in small fields and non‐equilibrium conditions

IJ Das, P Francescon, JM Moran, A Ahnesjö… - Medical …, 2021 - Wiley Online Library
… For example, f msr in Gamma Knife, CyberKnife and … and 10 cm for a field size of 10 cm
× 10 cm defined at a source to … Emphasis is placed on treatment planning dose calculation …

Shielding characteristics of nanocomposites for protection against X-and gamma rays in medical applications: effect of particle size, photon energy and nano-particle …

E Mansouri, A Mesbahi, R Malekzadeh… - Radiation and …, 2020 - Springer
… There is a wide body of information in the literature regarding … The gamma radiation sources
in this study were 137 Cs (0.662 … They also found that increasing the energy of the gamma

[HTML][HTML] Kidney dosimetry in 777 patients during 177Lu-DOTATATE therapy: aspects on extrapolations and measurement time points

M Sandström, N Freedman, K Fröss-Baron, T Kahn… - EJNMMI physics, 2020 - Springer
… In parallel to dose planning before external beam … dose is based on the activity distribution
and kinetics over time for the relevant organs and tissues, generally obtained by gamma

Neutron dose and its measurement in proton therapy—current state of knowledge

RA Hälg, U Schneider - The British journal of radiology, 2020 - academic.oup.com
… of neutron ambient dose equivalent in a specific location, the … measurements of neutron
and gamma-ray doses in a water … Bragg peak with a modulation of 10 cm from a pencil beam …

EpiXS: A Windows-based program for photon attenuation, dosimetry and shielding based on EPICS2017 (ENDF/B-VIII) and EPDL97 (ENDF/B-VI. 8)

FC Hila, A Asuncion-Astronomo, CAM Dingle… - Radiation Physics and …, 2021 - Elsevier
… plots with the most prominent appearing near the curve of the K-… The energy of this gamma
ray (88.0336 keV) is found in-between … The effective atomic numbers for borosilicate glass …

Gamma radiation shielding properties of some Bi-Sn-Zn alloys

N Rani, YK Vermani, T Singh - Journal of Radiological Protection, 2020 - iopscience.iop.org
… atomic number, measured experimentally, were found to be in close … the most sensitive organ
of the human body, the brain [6]. … The detector and source were kept at a distance of 10 cm

Small-field radiotherapy photon beam output evaluation: detectors reviewed

SE Lam, DA Bradley, MU Khandaker - Radiation Physics and Chemistry, 2021 - Elsevier
… stereotactic field diode (SFD) are close to unity for the smallest field … , all of which are based
on a 10 × 10 cm 2 reference field. The … EBT3 in terms of gamma evaluation passing rates and …

[HTML][HTML] EANM Dosimetry Committee series on standard operational procedures for internal dosimetry for 131I mIBG treatment of neuroendocrine tumours

J Gear, C Chiesa, M Lassmann, PM Gabiña, J Tran-Gia… - EJNMMI physics, 2020 - Springer
… volumes ranging in diameter up to 10 cm or more. Larger volumes … based on bio-kinetics,
particularly the whole-body absorbed … As gamma cameras are not optimised for high-activity …

Investigation and mapping of natural and artificial radioactivity in sediment samples from Borçka Black Lake, Artvin-Turkey

S Dizman, T Akdemir, CM Yeşilkanat… - International Journal …, 2024 - Taylor & Francis
… can cause certain damage to the body after a while, and … that the distribution of absorbed
gamma dose rate (AGDR) level … in this study are close to the concentrations found in Brullus, …