Rapid and Accurate Measurement of the Na+/K+ Balance in Urine for Remote Patient Monitoring Using a Symmetric Electrode Architecture

G Bouilly - Analytical Chemistry, 2023 - ACS Publications
… is the liquid junction potential from the reference electrode. In … This is therefore challenging
to build a perfectly symmetric … rely on a reference electrode to measure the Na + /K + ratio in …

Determination of ions in ash using ion-selective electrodes

D Saxena - 2023 - doria.fi
… and the reference electrode, including the liquid junction as … against a reference potential
value provided by the reference … is a primary reference electrode which is established to have …

Recent advances in solid-contact ion-selective electrodes: Functional materials, transduction mechanisms, and development trends

Y Shao, Y Ying, J Ping - Chemical Society Reviews, 2020 - pubs.rsc.org
… The electrical potential difference between the reference … will be quickly re-established and
the phase boundary potential (E PB … When performing the direct potentiometric measurement …

Analysis of Copper (II) Ions in Human Blood Using a New Solid-Contact PVC Membrane Potentiometric Sensor Based on a N, N′-Bis (salicylidene)-1, 3 …

N Aslan, Z Koçak, H Kormalı Ertürün… - Analytical and …, 2023 - analchemres.org
… Ag/AgCl double junction reference electrode (Orion 900200) … in a direct potentiometric
measurement of copper(II) in the prepared solution. The linear range was determined by creating

Relationship between measured and prescribed dialysate sodium in haemodialysis: a systematic review and meta-analysis

JKC Ng, B Smyth, MR Marshall, A Kang… - Nephrology Dialysis …, 2021 - academic.oup.com
Background Dialysate sodium (DNa) prescription policy differs between haemodialysis (HD)
units, and the optimal DNa remains uncertain. We sought to summarize the evidence on the …

Eco-conscious potentiometric sensing: a multiwalled carbon nanotube-based platform for tulathromycin monitoring in livestock products

OG Hussein, HH Monir, HE Zaazaa, MM Galal - BMC chemistry, 2024 - Springer
established regulations governing TUL's maximum residue … and a double-junction Ag/AgCl
reference electrode with an inner … Direct potentiometric measurements were carried out using …

Bias in the determination of dialysate sodium concentration set according to conductivity relative to indirect ion-selective measurement techniques

R Sheikh, S Hiremath, EG Clark, A Akbari… - Kidney International …, 2020 - kireports.org
Results Data are presented from 196 measurements taken from 50 simulated dialysis sessions
in which dialysate sodium was measured using the plasma mode and 35 measurements …

Vitreous humor endogenous compounds analysis for post-mortem forensic investigation

N Pigaiani, A Bertaso, EF De Palo, F Bortolotti… - Forensic science …, 2020 - Elsevier
… Due to its established relevance in toxicology, a literature review highlighting the use of VH
… (PMI), which can be helpful in determining the cause of death. Consequently, the present …

Immobilization of molecular assemblies on 2D nanomaterials for electrochemical biosensing applications

S Berchmans, T Balamurugan - Immobilization Strategies: Biomedical …, 2021 - Springer
… interface created at the junction of the sensing element and … , are employed for direct
potentiometric detection of various … is of major importance as the extra build-up of cholesterol and …

An Integrated Geochemical Spatial and Temporal Survey of Low Temperature Thermal Springs to Characterize the Geothermal Resource of a Volcano (Piton Des …

B Bénard, V Famin, B Sanjuan, F Vimeux… - Available at SSRN … - papers.ssrn.com
… first phase and by direct potentiometric determination for the 225 … show a trend towards the
Na+K pole 268 in the cation plot … fluid circulation; and 4) determining the temperature of fluid/…